Page 1
IMPACTOR IP700 WASTE COMPACTORS INSTALLATION, OPERATING AND MAINTENANCE MANUAL PLEASE LEAVE WITH OPERATOR IP700 – SERIES 3 Imperial Machine Company Limited Unit 1, Abbey Road Wrexham Industrial Estate Wrexham LL13 9RF Tel: +44 (0)1978 661155 Fax: +44 (0)1978 729990 Service Fax: +44 (0)1978 667766...
Page 3
IP700 EC DECLARATION OF CONFORMITY (Guarantee of Production Quality) We, Imperial Machine Company Limited of: Unit 1, Abbey Road, Wrexham Industrial Estate, Wrexham, LL13 9RF Declare under our sole responsibility that the machine IP700 – SERIES 3 As described in the attached technical documentation, are in conformity with the protection requirements of the Electromagnetic Compatibility Directive 2004/108/EC and manufactured in accordance with harmonised standards EN 61000-6-1: 2001 Immunity and EN 61000-6-3: 2001 Emissions (plus product specific standards).
GUARANTEE Each Impactor is guaranteed by IMC for twelve months from the date of its purchase from IMC, or from one of its stockists, dealers or distributors. The guarantee is limited to the replacement of faulty parts or products and excludes any consequential loss or expense incurred by purchasers.
For the installer: These instructions contain important information designed to help the user obtain the maximum benefit from the investment in an IMC Waste Compactor. Please read them carefully before starting work, and consult with the supplier in the event of any queries.
IP700 ELECTRICAL CONNECTION Standard machines are supplied as single phase units. 3 phase machines are supplied as variation to specification. Before making the electrical connection check that the voltage of the supply is suitable for the machine. The details of the machine are on a rating label located on the rear panel. All machines should be connected to a switched outlet.
IP700 OPERATING : · Turn the key switch to select the ON position. · Select NORMAL or CONSTANT operation. If NORMAL is selected the unit will cycle once only: the ram will move to the down position, pause for four seconds and return to the fully up position where it will stop. CONSTANT leaves the ram in the down position until released by turning the switch from constant to normal.
· Check that the bin switch is functioning by metering to check that with the bin in, the contacts are made. If difficulty persists, contact the supplier or IMC Service Desk (01978 667743).
For installations outside the UK please contact your supplier. For information on IMC spares and service support (if applicable), please call IMC on +44 (0)1978 661155. Alternatively, contact us via email or fax:...
Page 13
IP700 PARTS LIST IMPACTOR IP700 , August 2003 To be read in conjunction with Figs 1-2. NB Before ordering please read the note on page 8 Item Part No. Description Item Part No. Description E56/070 Frame Welded Assy E56/173 Floor Plate...