ROTOTILT Secure Lock Translation Of The Original Instructions

Advertisement

Secure Lock™
Translation of the Original Instructions
_EN
_0000 2017-03-27
2200394

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Secure Lock and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ROTOTILT Secure Lock

  • Page 1 Secure Lock™ Translation of the Original Instructions _0000 2017-03-27 2200394...
  • Page 2 Overview The products described in this document consist of components for SecureLock™, and RPS SecureLock™ for the quick coupler mounted under Rototilt ® Refer to the illustrations and lists below and on the following pages. Components 1. Harness, boom Coupler...
  • Page 3 Swedish, Finnish, Norwegian, German, Danish and French. Select the flag for the required language. Now confirm with OK. Perform a restart. INFO - A system restart is required to activate the change. © Rototilt Group AB 2017-03-27 English 2200394_ _0000...
  • Page 4: System Information

    Supply Voltage - current supply to the tiltrotator and/or machine coupler. RT = Tiltrotator EX = Machine coupler Angle The menu provides information about the current rotation angle. The RPS icon is displayed if the function is activated. © Rototilt Group AB 2017-03-27 English 2200394_ _0000...
  • Page 5 The system shows a reminder, after every 8 hours of operation. The reminder indicates that a requisite service must be carried out. See the Instruction for use for Rototilt® If the ILS option is specified, the 8 hours of operation reminder is automatically switched off.
  • Page 6: Operation

    Press the OK function key. A visual warning will be shown at 30 second intervals as long as Rototilt® is running without a tool and remains visible until any key is pressed again. Secure Lock™ for the machine...
  • Page 7: Troubleshooting

    The warning can be acknowledged with any key. Communications The warning indicates that communications via the CAN-bus have failed. For detailed troubleshooting: see Schematics, Control Unit - Troubleshooting. © Rototilt Group AB 2017-03-27 English 2200394_ _0000...
  • Page 8 Red light comes on for 1 second at the same time as the yellow Rotation sensor fault. light from the zero position sensor goes out. © Rototilt Group AB 2017-03-27 English 2200394_ _0000...