Block Title
Parameter
KEYPAD RUN REV
KEYPAD JOG FWD
KEYPAD JOG REV
LOC. HOT START
INPUT
OPERATING MODE
COMMAND SELECT
ANA CMD INVERSE
ANA CMD OFFSET
ANA 2 DEADBAND
ANA 1 CUR LIMIT
OUTPUT
OPTO OUTPUT #1
OPTO OUTPUT #2
OPTO OUTPUT #3
OPTO OUTPUT #4
ZERO SPD SET PT
AT SPEED BAND
SET SPEED
ANALOG OUT #1
ANALOG OUT #2
ANALOG #1 SCALE
ANALOG #2 SCALE
POSITION BAND
CTRL BASE SPEED
VECTOR
CONTROL
FEEDBACK FILTER
FEEDBACK ALIGN
CURRENT PROP
GAIN
CURRENT INT GAIN
Proprietary and Confidential
Level 1 Blocks–S/W Ver. 3.12
P#
1304
1305
1306
1307
1401
1402
1403
1404
1405
1406
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1601
1602
1603
1604
1605
MPS-2224-AI Rev 00
Factory
HP Indigo
Setting
Setting
ON
OFF
ON
ON
ON
OFF
OFF
OFF
KEYPAD
SERIAL
(15SPD)
+/-10 VOLTS
SERIAL
(+/-10V)
OFF
OFF
0.0 %
0.0 %
0.00 V
0.00V
OFF
OFF
READY
READY
ZERO
ZERO
SPEED
SPEED
AT SPEED
AT SPEED
FAULT
FAULT
200 RPM
1 RPM
100 RPM
1000 RPM
Rated Motor
1 RPM
Speed
ABS SPEED
ABS SPEED
MOTOR
MOTOR
CURRENT
CURRENT
100 %
100 %
100 %
100 %
CALC
3
CALC
1480 RPM
(1500 RPM)
CALC
5
FORWARD
FORWARD
20
10
(35)
50
13
(16)
MPS-2224-AI