STEP FIVE: Log Placement.
SIDE VIEW
(1) LOG SET. Place large LOGS on filled BURNER PAN. Allow 2" to 3" space between front and rear logs. Lay smaller logs on
bottom in cross position. CAUTION: Crowded logs will cause poor combustion and result in excessive soot formation.
(2) DRIFTWOOD or MANZANITA STUMP. Stand large DRIFTWOOD or STUMP piece slightly ahead of center on filled
BURNER PAN. Surround with EMBER MAGIC to simulate burned embers. Large pieces of EMBERS should be inserted 1/2" into
PAN MEDIUM for best effect. On larger sets, arrange companion pieces to fill up balance of burner.
(3) PINE CONE SET or FIREBALLS. Mound EMBER MAGIC in middle of PAN. Place large PINE CONES or FIRE BALLS
around edge of BURNER and over mound of EMBER MAGIC. Fill in gaps with smaller PINE CONES.
STEP SIX: Lighting Instructions and Operation.
IMPORTANT: CHIMNEY DAMPER MUST BE WIDE OPEN
MANUAL MATCH LIGHTING.
• Standard Match Lit Set
f i r e - p a r t s . c o m
(Applies only to Natural Gas Models CS or CS-W)
1. Place lighted match on embers near inlet end of burner. DO NOT HOLD MATCH IN HAND ! Move away from front of fireplace.
2. Slowly open FIREPLACE GAS SUPPLY VALVE and wait for burner to light. (See FIGURE 7)
3. Adjust FIREPLACE GAS SUPPLY VALVE for desired flame height.
4. SHUTDOWN: Close FIREPLACE GAS SUPPLY VALVE completely
MANUAL MATCH LIGHTING WITH ACCESSORY V17 VALVE.
• Match Lighted V17 Valve
(Applies only to Natural Gas Models CS or CS-W)
1. Ensure that MANUAL V17 VALVE is completely closed. (See FIGURE 5)
2. Open FIREPLACE GAS SUPPLY VALVE. (See FIGURE 7)
3. Place lighted match on embers near inlet end of burner. DO NOT HOLD MATCH IN HAND !
4. Slowly open MANUAL V17 VALVE and wait for burner to light.
5. Adjust MANUAL V17 VALVE for desired flame height.
6. SHUTDOWN: Close MANUAL V17 VALVE and FIREPLACE GAS SUPPLY VALVE completely
PILOT LIGHTING USING ACCESSORY SPK3.
• SPK3-CS (Applies to Natural Gas Models CS or CS-W)
• SPK3-CA (Applies to Propane/LP Gas Models CA or CA-W).
SPK-3CS/CA LIGHTING INSTRUCTIONS.
1. Bleed all air from piping leading to control. Carefully re-tighten connection.
2. Turn CONTROL KNOB pointer to "OFF" position. Wait 5 minutes before
lighting.
3. Turn CONTROL KNOB pointer to "PILOT" position. Depress CONTROL
KNOB and hold down 60 seconds after lighting pilot burner. Release
CONTROL KNOB. Pilot will remain lighted.
4. Turn CONTROL KNOB partially towards the "ON" position. After gas fills
burner pan medium, burner will light. Dial may then be turned to full "ON" or
to desired flame height.
5. If main or pilot burner extinguishes, turn CONTROL KNOB to "OFF"
position. Wait five minutes and repeat above lighting procedure from step 1.
FRONT VIEW
.
6
TOP VIEW
.
PILOT
ADJUSTMENT
SCREW
+
AT PILOT POSITION
SLIGHT PUSH TO
TURN OFF
FULL PUSH TO
LIGHT
+
OFF
ON
HEAT SHIELD
CONTROL KNOB
Figure 14

Advertisement