GENERAL INSTALLATION INSTRUCTIONS
ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS FOR RASMUSSEN
CA; CA-W (Wide) for use with Propane (LP) Gas
IMPORTANT
WARNING:
alteration, service or maintenance can cause
injury
or
property
instructions thoroughly before installation. For
assistance or additional information, consult
your gas log dealer, qualified installer, service
agency or gas supplier.
f i r e - p a r t s . c o m
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
THIS GAS LOG SET MUST BE INSTALLED IN A FULLY VENTED
SOLID-FUEL BURNING FIREPLACE WITH A WORKING FLUE
The minimum permanent free opening of the fireplace chimney or chimney damper must be at least 39 square inches
based on a minimum chimney height of at least 8 feet. The area of the flue must not be less than 1/10 the area of the
fireplace opening. The flue must exhaust all products of combustion.
The chimney damper must be fixed in a manner to maintain permanent free opening as outlined above at all times. To
accomplish this, install the damper clamp (provided) on the edge of the damper blade to prevent
its closing, drill a hole or holes in the damper, or remove damper completely.
The minimum size of the fireplace in which the log set is to be installed must be as follows:
LOG SET SIZE
18 INCH
24 INCH
30 INCH
.
Glass doors must be wide open when burner is lighted
THIS BURNER IS FOR USE IN FULLY FUNCTIONING WOOD BURNING
THE FLUE MUST VENT ALL PRODUCTS OF COMBUSTION.
Custom Pan Burner
VENTED CUSTOM PAN BURNER MODELS:
CS; CS-W (Wide) for use with Natural Gas
Improper
installation,
damage.
Read
IMPORTANT INFORMATION
CONSTRUCTED OF NON COMBUSTIBLE MATERIAL.
MINIMUM FIREPLACE SIZE IN INCHES
HEIGHT
16
16
16
.
to allow air for safe combustion and venting.
FIREPLACE WITH THE DAMPER WIDE OPEN.
12028 E. Philadelphia St. Whittier , CA 90601 U.S.A.
(562) 696-8718
E-Mail: gaslogs@riwinc.com Web http://www.riwinc.com
READ THESE INSTRUCTIONS CAREFULLY BEFORE
STARTING INSTALLATION OF LOG SET.
FOR YOUR SAFETY
these
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
fire department.
D E P T H
13
13
13
.
.
FAX (562) 698-3510
WIDTH
CHIMNEY
24
7 INCH DIAMETER
32
7 INCH DIAMETER
36
8 INCH DIAMETER
.
CSCA-799
.

Advertisement

loading

Summary of Contents for Rasmussen CS

  • Page 1 E-Mail: gaslogs@riwinc.com Web http://www.riwinc.com GENERAL INSTALLATION INSTRUCTIONS ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS FOR RASMUSSEN VENTED CUSTOM PAN BURNER MODELS: CS; CS-W (Wide) for use with Natural Gas CA; CA-W (Wide) for use with Propane (LP) Gas IMPORTANT READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OF LOG SET.
  • Page 2 IMPORTANT INFORMATION (continued) A fire place screen must be in place when the log set is in The gas log set and its individual shutoff valve must be operation and, unless other provisions for combustion air disconnected from the gas supply piping system during are provided, the screen shall have opening(s) any pressure testing of that system at test pressures in introduction of combustion air.
  • Page 3 B O LT A N D F I B E R WASHER MUST BE INSTALLED TO ENSURE GAS TIGHT INTEGRITY. Standard Match Lighted • (For use only with Natural Gas Models CS, CS-W) Figure 3 WARNING: A SAFETY PILOT MUST BE...
  • Page 4: Top View

    Accessory Safety Pilot Lighting Kit SPK3: • SPK3-CS (For use with Natural Gas Models CS, CS-W) • SPK3-CA (For use with Propane Gas Models CA, CA-W) A. Insert Burner Orifice. 1. Thread ORIFICE SPUD into V A L V E O U T L E T F I T T I N G and wrench tighten.
  • Page 5 STEP TWO: Burner Pan Positioning. REAR WALL 1. Place BURNER PAN inside firebox as far to the rear as possible. Then center BURNER PAN left to right. SIDE VIEW See Figures 10 and TOP VIEW Figure 10 Figure 11 STEP THREE: Gas Supply Connection. ENSURE THAT GAS SUPPLY TYPICAL INSTALLATION TO FIREPLACE IS TURNED OFF...
  • Page 6 6. SHUTDOWN: Close MANUAL V17 VALVE and FIREPLACE GAS SUPPLY VALVE completely PILOT LIGHTING USING ACCESSORY SPK3. • SPK3-CS (Applies to Natural Gas Models CS or CS-W) • SPK3-CA (Applies to Propane/LP Gas Models CA or CA-W). SPK-3CS/CA LIGHTING INSTRUCTIONS.
  • Page 7: Customer Maintenance

    See detailed instructions included with S a f e t y P i l o t Lighting Kits R P K 1 - C S / C A , R P K 1 - F 1 0 - C S...
  • Page 8: Customer Responsibility

    (2) RASMUSSEN shall not be liable for any loss, damage, suitable for a particular purpose, for a period of: incidental or consequential damages of any kind, whether based...