Note: At least one RadioLINK Smoke/Fire/Heat Alarm is required to make the EIB170RFAU Alarm operational. This is not supplied with the EIB170RFAU and must be obtained separately. Important: Read these instructions, together with those from the separate RadioLINK Smoke/ Heat/CO Alarms and accessories before installation.
Leaving the unit operating without mains connected will completely deplete the battery and possibly damage it. (If the EIB170RFAU is not being used for a prolonged period and cannot be left plugged in to the mains, then disconnect the battery).
Page 3
Battery Battery Plug Latch Figure 2 plug, open). Place the battery in the compartment ensuring the notch in the battery is used to leave clearance for the plug and sockets (see Figure 3). Battery Clearance Notch Figure 3 Shows battery orientation - Dress the battery leads as shown, replace the battery cover and push firmly down on the two latches The Strobe Module can be left on a table or permanently fixed to the wall using the screws and plastic plugs enclosed.
Page 4
The primary vibration pad is supplied already plugged into its locking socket on the rear of the EIB170RFAU Strobe Module (see Figure 1a). Place the vibration pad under the pillow or mattress. It is important that the person in the bed can feel the vibration – check it is sufficient to wake a person by lying on the bed and pressing the test button on the Strobe Module –...
3.1.3 Press and hold the Strobe Module House Code button until the blue RadioLINK light comes on. Release it and the light will flash every five seconds. 3.1.4 When all units are set into ‘House Code Mode’ they should signal to each other and set-up their network automatically.
4.1 AFTER INSTALLATION 4.1.1 Check that all RadioLINK Alarms and Accessories are powered correctly. 4.1.2 Check that the green light on the EIB170RFAU Strobe Module is continuously lit. 4.1.3 Press the test button on all RadioLINKED Smoke/Heat/CO Alarms, Remote Controls and Manual Call Points in turn, and check that all other Smoke/Heat/CO Alarms in the system alarm after about 4 seconds and that the strobe and vibration pad activate.
the battery will need to be replaced. Contact the nearest address in this leaflet for advice about getting a replacement. The battery also needs to be replaced if it is over 5 years old (see “replace battery by” date on side panel). To remove the battery reverse the instructions in the first part of section 2. Contact nearest address at the end of this leaflet on obtaining a replacement battery.
5. FIVE YEAR GUARANTEE Brooks guarantees this device for five years from the date of purchase against any defects that are due to faulty materials or workmanship. This guarantee only applies to normal conditions of use and service, and does not include damage resulting from accident, neglect, misuse, unauthorised dismantling, or contamination howsoever caused.
Page 9
Remove Primary protection Vibration Pad plug before connecting accessories 180mA(max) 20mA(max) Aux1 Aux2 Template for Mounting Screws Drill Holes Here Figure 5...