Fig. 4
Unit #1
Already installed
BLACK &
WHITE
POWER
CONNECTIONS
C
FOR AC-VERSION
(MULTI HOOK-UP); Fig. 4 and Fig. 4a
1. Remove COVERS from all CONTROL BOX (2).
Fig. 4 and Fig. 4a.
2. Remove SOLID BLACK PLUG GROMMET (17) from
left side of all CONTROL BOX (2). Replace with GRAY
GROMMET (18). (Supplied with each Faucet).
Fig. 4 and Fig. 4a.
3. Feed the EXTENSION CABLE (3) from the Faucet
through GROMMET (4) and connect it to the
SOLENOID CABLE (5). Fig. 4 and Fig. 4a.
4. Feed the EXTENSION CABLE (8) from the Faucet
through GROMMET (4a) and connect to either of the
two terminals at the one end of the Y-ADAPTER (13).
Connect the 10 ft. EXTENSION (11a) to the other
terminal at the same end of the Y-ADAPTER (13).
Fig. 4 and Fig. 4a.
5. Feed the other end of the 10 ft.EXTENSION (11b)
through the two GRAY GROMMETS (4a and 4b) and
connect to the single terminal end of the next unit's
Y-ADAPTER (13). Place Y-ADAPTER (13) into
CONTROL BOX (2) as shown in Fig. 4 and Fig. 4a.
6. Repeat Steps above for each additional Unit, for a
Max. of 15 Units on one AC POWER SUPPLY.
7. Replace CONTROL BOX COVERS. Tighten cover
screws firmly.
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS
supplied cables, or cutting, splicing or modifying
any components will void the warranty.
AC POWER
SUPPLY
OR
Unit #2
*MAXIMUM OF 15 UNITS PER
AC POWER SUPPLY.
10' MAXIMUM CABLE
LENGTH BETWEEN UNITS.
Fig. 4a
Unit #1 Detail
11a
8
5
17
18
13
3
8
Unit #3
10 ft.
EXTENSION
CABLE
4a
4
AC POWER
YOU CAN USE EITHER THE PLUG-IN
OR HARD-WIRED TRANSFORMER.
M965613 REV. 1.9 (12/17)
4b
11b
2