START-UP / MAINTENANCE

HAND WASH SENSOR OPERATION;
A
Fig. 1
!
Prior to making power connection, make sure
detection zone is not obstructed. Sensor is
self adjusting. Keep detection zone clear for 15
seconds after power is connected.
When the Sensor detects a user, the water immediately
starts to flow. Water flow will stop 1.5 seconds after user
is out of sensor range. This comfort timer allows the user
to move his hands without the flow cycling on and off. As
a precaution, a safety timer will turn off the water after
the sensor has been blocked for 55 seconds. Water flow
will resume when the blockage is removed from the
detection zone and the sensor is activated again.
B
HOW TO INSTALL AND CHANGE
BATTERY; Fig. 2
1. Remove COVER from CONTROL BOX (1).
2. Disconnect BATTERY HOLDER (3) from SENSOR
CABLE (5).
3. Remove old BATTERY from BATTERY HOLDER (3).
Install new BATTERY (2) making sure the terminal side
is inserted first and shape of the battery follows the
shape of the BATTERY HOLDER (3).
!
Prior to making power connection, make sure
detection zone is not obstructed. Sensor is
self adjusting. Keep detection zone clear for 15
seconds after power is connected.
4. To change PWRX BATTERY PACK (4), unplug and
replace with new Power Pack.
5. Reconnect BATTERY HOLDER (3) to SENSOR
CABLE (5).
6. Replace CONTROL BOX COVER. Tighten cover screws
firmly.
HOW TO CLEAN FILTER
C
ASSEMBLY; Fig. 3
Before opening CONTROL BOX
CAUTION
disconnect AC power supply.
1. Remove CONTROL BOX COVER.
2. Close SUPPLY STOP (13) with 4mm Hex wrench.
Note: Activate sensor to keep water flowing out of
faucet while shutting off.
3. Unthread FILTER ASSEMBLY (6) using a 7/16" socket.
4. Pull out the FILTER ASSEMBLY (6), remove and clean
white debris cup and filter screen.
5. Install the FILTER ASSEMBLY (6) back in its place and
tighten with a 7/16" socket.
Caution: Do not over tighten.
6. Open SUPPLY STOP (13) with 4mm Hex wrench.
7. Replace CONTROL BOX COVER. Tighten cover
screws firmly.