5
In (A )
1
1,5
140G-J
40
40
60
6
In (A )
0 ,2
0 ,2 5
14 0 G-J
4 0
8
7
Electronic default setting
Settaggio di default elettronico
elektronische Default Einstellung
Configuration par défaut
électronique
Ajuste de default electrónico
DIR 1000721R0510 Version 00
2
2,5
3
3,5
4,5
80
100
120
140
180
I4 (In)
0 ,4 5
0 ,55
0 ,75
0 ,8
10
18
2 2
3 0
3 2
L
t1
S
I
G
Example - Esempio - Beispiel - Exemple - Ejemplo
In = 40A
I3 = 40x(1,5+5,5)=280A
I3 (In)
5,5
6,5
7
7,5
8
220
260
280
300
320
Example - Esempio - Beispiel - Exemple - Ejemplo
In = 40A
I4 = 40x(0,2+0,25)=18A
t4 = 0,2s @ I>I4
1
4 0
15A
60 s
Off
4,5 x In
Off
(3)
8,5
9
10
340
360
400