Download Print this page

Kruger HUGO KCI30 User & Installation Manual page 14

Advertisement

Electrical
The cooktop must connect to a separate, grounded, single-phase, AC ONLY electrical supply
with their own circuit breaker. The connection must be made in accordance with provincial and
municipal regulations and codes. This cooktop must be supplied with the proper voltage and
frequency and amperage, which is protected by a proper-sized circuit breaker or time delay fuse.
!
The cooktop conduit wiring is approved for copper wire connection only. Us only special
connections approved for joining copper and aluminium wires conform with local codes and
ordinances.
Red Wire
White Wire
Green Wire
Grounding
Before making any electrical connections, make sure that:
The safety circuit-breaker and the electrical system are able to withstand the load of the
appliance (see nameplate).
The power supply system has a grounding connection in good working order in accordance
with the regulations in force;
The socket or omni polar switch used are easily accessible with the appliance installed.
Cable from Power Supply
Cable from Appliance
14
Black Wire
Black Wire
Junction Box

Advertisement

loading

This manual is also suitable for:

Hugo kci36