Dear Customer,
To guarantee the safety and correct working of the appliance,
please read the following instructions CAREFULLY before begin-
ning the installation.
IMPORTANT:
Make sure that the power supply has been disconnected before
performing the installation or electrical connection of the appliance.
Installation, electrical connections and settings must be carried
out by a qualified person in line with local regulations.
If these installation instructions are not followed the product may
be damaged.
For optimal performance, the appliance must be installed co-
rrectly (installation of the unit, ducts and air replacement inlets).
This extractor fan is designed for the ventilation of households or
similar premises. Do not use for any purpose other than that for
which it was designed.
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental ca-
pabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall
not play with the appliance.
Cleaning and user maintenance shall not be made by children
without supervision.
The fan is to be installed so that the blades are more than 2,3 m
above the floor.
This extractor fan does not produce radio/television interference
(Directive 2004/108/EC).
Prior to piping installation, consult the municipal by-laws on air
outlets and request permission from the person responsible for
the building.
Precaution must be taken to avoid the backflow of gases into the
room from the open gas pipe or from other open-flame devices.
The room must have adequate ventilation if this appliance is used
simultaneously with other appliances that run on gas or other fuels.
Do not install the exhaust conduit (A, B) of the extractor fan to a
chimney flume, ventilation pipes, hot air ducts or ducts used to
evacuate fumes from appliances that run on gas or other fuels.
DO NOT install this product in areas with the follow characte-
ristics:
• Excess of oil or grease.
• Areas with corrosive, explosive or flammable liquids, gases or
vapours.
• Areas with temperatures higher than 60 °C or lower than -5 °C.
• Areas exposed to the environment (rain, sun, snow, etc.)
• Areas with possible obstacles that obstruct the access to the
fan.
EN
ENGLISH
The product and its parts must not be submerged in water or
other liquids.
The IP rating is only valid if the installation of the appliance com-
plies with what is indicated in this manual.
The manufacturer declines all responsibility for personal injury
or damage to animals or objects caused by inappropriate use of
the appliance according to the warnings for installation, use and
maintenance described in this instruction manual.
After finishing the installation these instructions should be given
to the owner/user of the appliance.
INSTALLATION:
Before starting the installation, check that the propeller is not de-
formed or damaged, that it can turn freely, and that no foreign
body is lodged inside the outer casing.
This type of tubular extractor is designed to work within any sec-
tion of the air exhaust duct (rigid or flexible) in either a horizontal
or a vertical position.
The appliance shall be installed according to the attached graphic
documentation (see fig. 1 and 2)
• Loosen the 2 screws (D) and lift the flanges (E). Take the casing
assembly (F) out of its housing.
• Place the bracket + openings (G) in the place where you want
to install the extractor (wall or ceiling) and mark the holes (H).
• Make four holes with a suitable drill bit and secure the bracket
using the plugs and screws included with the appliance.
Is recommended that you place the appliance at a distance equal
to or greater than one metre from the bend or the closest suction-
expulsion opening.
• Join the suction (A) and expulsion (B) conduits to the nozzles (I)
by flanges or resistant adhesive tape
It is important that the diameter of the tube should be equal to
the diameter of the openings to ensure efficient operation of the
appliance.
• Replace the casing (F) in its housing in such a way that the
air circulation direction indicated by the arrows (J) and the cable
outlet direction are as desired.
Close the flanges (E) and tighten the screws (D)
Whether the assembly is done with an individual exhaust tube
or with a direct outlet, air grilles must be installed that comply
with national safety requirements for preventingaccess to the fan
blades Make sure that there is no obstacle blocking the flow of air.

ELECTRICAL CONNECTION:

Make sure that the voltage (V) and frequency (Hz) of the power
supply correspond to the values indicated on the nameplate.
The appliance must be able to be disconnected from the mains
electricity supply after installation.