Routine
Number
Description
Error Code
Meaning
\,
TR0318
LED on status (04) should be present.
0918
Bad sense bit found.
"~/
TR0321
BOT status (01) should not be present; that
0921
Bad sense bit found.
is, sense bit (01) should be on.
r/r'"
TR0324
EOT status (80) should not be present.
0924
Bad sense bit found.
/
~
..
TR0327
Erase active (08) status should not be present.
0927
Bad sense bit found.
TR0330
Erase active (08) status for track 0 (format
0930
Bad sense bit found.
track) should be present.
Note:
This test leaves the erase coil on.
TR0333
Erase active (08) status for track 1 (data track)
0933
Bad sense bit found.
~
,
should be present.
/
Note:
This test leaves the erase coil on.
TR0336
Select magnet active status (20) should not be
0936
Bad sense bit found.
present.
TR0337
Select magnet active status (20) for forward
0937
Bad sense bit found.
tape motion should be present.
Note:
This test leaves the forward tape and
select magnet active commands on.
'.
,
TR0338
Select magnet active status (20) for reverse
0938
Bad sense bit found.
tape motion should be present.
Note:
This test leaves the reverse tape and
select magnet active commands on.
TR0348
Cartridge in place status (10) should be present.
0948
Bad sense bit found.
TR0349
File protect status (02) should be present.
0949
Bad sense bit found.
TR0350
EOT status (80) should not be present.
0950
Bad sense bit found.
"-
,
~'
"