OSP Menu
MOl (MAP Diagnostic Integration)
Loading:
1. Select the MOl section number from the OSP menu.
2.
Enter the MOl section number.
3. Press the EXECUTE key.
This procedure loads and automatically runs the MOL
To stop the MOl and return to the MOl options, press the AnN key.
The following message might appear if the MOl halts:
I
ENTER Y OR N (B,
0,
T)
Y
=
Yes}
N
=
No
B
=
Back:
Refers to an answer to a specific question on the display
screen. Enter the appropriate answer and press the
EXECUTE key.
You can enter B or BXX and press the EXECUTE key.
XX is the number of steps you want to back up in the
trace table.
0= Option:
You can enter 0 and press the EXECUTE key to display
the MOl options.
T
=
Trace:
You can enter T and press the EXECUTE key to display
the
s~eps
that were executed along with the decision
(Y or N) that was displayed. To obtain a copy of the
trace table, press the HOLD key, press and hold the
CMO key, and press the; key.
J
I
MOl ran OK.
' - -
Return to MAP
Intervention required. Read
the display and take the
appropriate action.
RESTART
4-30
or
press ATTN
key twice and
select the next