Download Print this page
Watts OneFlow+ OFPSYS Installation, Operation And Maintenance Manual

Watts OneFlow+ OFPSYS Installation, Operation And Maintenance Manual

Salt-free scale prevention and water filtration system
Hide thumbs Also See for OneFlow+ OFPSYS:

Advertisement

Quick Links

Installation, Operation and
Maintenance Manual
OneFlow
+ Salt-Free Scale
®
Prevention and Water Filtration
System
Model OFPSYS
WARNING
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
WARNING
!
If you are unsure about installing your Watts OneFlow
contact a Watts representative or consult a professional plumber.
You are required to thoroughly read all installation instructions
and product safety information before beginning the installation
of this product. FAILURE TO COMPLY WITH PROPER
INSTALLATION AND MAINTENANCE INSTRUCTIONS
COULD RESULT IN PRODUCT FAILURE WHICH CAN CAUSE
PROPERTY DAMAGE, PERSONAL INJURY AND/OR DEATH.
Watts is not responsible for damages resulting from improper
installation and/or maintenance. Local building or plumbing codes
may require modifications to the information provided. You are
required to consult the local building and plumbing codes prior to
installation. If this information is not consistent with local building or
plumbing codes, the local codes should be followed.
Save manual for future reference.
Refer to the enclosed for operating parameters to ensure proper
use with your water supply.
• Use only lead-free solder and flux for sweat-solder connections,
as required by state, province and federal codes.
• Handle all components of the system with care. Do not drop,
drag or turn components upside down.
• Be sure the floor under the system is clean, level and strong
enough to support the unit if the OneFlow
on the floor.
• Install the system in a protected area.
• Do not attempt to treat water over 100°F (38°C) with the system.
• Always connect the system to the main water supply pipe before
the water heater.
• Do not expose the system to freezing temperatures. Water
freezing in the system causes equipment damage.
• Do not install in direct sunlight. Ultraviolet rays from the sun
may cause damage.
• Do not use on water that is microbiologically unsafe or of
unknown quality.
+ system
®
+ system is situated
®
OneFlow
®
+ is
certified by the Water
Quality Association
(WQA) to NSF / ANSI
Standard 372 for
lead free.

Table of Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
+ Benefits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
®
Equipment Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Feed Water Chemistry Requirements. . . . . . . . . . . . . . . . . . . . . . 3
Contaminant Treatment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Notes to the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
+ System Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
®
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Changing the Filter Cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Note to the Home Owner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Introduction

The OneFlow
+ system is an economical and environ-
®
mentally friendly physical water treatment technology that
protects pipes, extends the life of appliances, and provides
better tasting water through filtration. The OneFlow
system is a dual cartridge-based system with a radial flow
20 micron carbon block cartridge which reduces sediment,
chlorine taste and odor, and an integrated OneFlow
prevention cartridge.
The OneFlow
+ system uses template assisted crystal-
®
lization to attract hardness minerals and convert them into
harmless, inactive microscopic crystal particles.
These crystals stay suspended in the water and are passed
to drain. The system requires very little maintenance, no
backwashing, no salt and no electricity. Typical hardness
problems, especially build-up of scale in heating elements,
pipes, water heaters, boilers and on fixtures, are reduced.
The OneFlow
+ system is not a water softener. It does not
®
add chemicals. It is a scale prevention device with proven
third party laboratory test data and years of successful
commercial, residential and food service applications. The
OneFlow
+ system is the intelligent scale solution and is a
®
great salt-free alternative to water softening (ion exchange)
or scale sequestering devices.
IOM-OFPSYS
OFPSYS
Pages
+
®
scale
®

Advertisement

loading

Summary of Contents for Watts OneFlow+ OFPSYS

  • Page 1: Table Of Contents

    Changing the Filter Cartridges ......5 If you are unsure about installing your Watts OneFlow + system ®...
  • Page 2: Setup

    2. Do not apply antiscalant before or after the OneFlow ® system. Equipment Specifications Watts OneFlow + systems are complete, self-contained, ® loaded with media and ready to use. A simple inlet and outlet connection is all that is required for installation. Please review operating pressures, temperatures and water chemistry ⁄...
  • Page 3: Feed Water Chemistry Requirements

    CAUTION Feed Water Chemistry Requirements • Do not let the system freeze. Damage to the housing may result. 6.5-8.5 Hardness (maximum) 75 grains (1282 ppm CaCO3) • System must be operated in a vertical position. Do not lay it down during operation. The system may be placed in any Water Pressure 10 psi to 90 psi (0.69 bar to 6.21 bar) position for shipping and installation but must be operated...
  • Page 4: Oneflow ® + System Parts

    Installation Instructions OneFlow + System Parts ® New system comes with the cartridges and outlet connector pre-installed. Installer should verify this prior to installation. How to install your OneFlow + system can also be found at: ® http://thescalesolution.com/residential NOTICE Please confirm that all items required are included in the kit ready for assembly and remove from carton.
  • Page 5: Changing The Filter Cartridges

    Changing the Filter Cartridges: Diagram B Diagram A 1. Turn off water at supply valve or at main valve to home. 2. Use the Multifunction Tool (Item 6) to release air from the system. This is done by taking the tool and unscrewing the Pressure Relief Valve (Item 5) –...
  • Page 6: Note To The Home Owner

    Note To The Home Owner Things to watch for: During the first 30-90 days: Your OneFlow + system will improve the properties of water ® throughout your home. Here are some things to expect and • Faucet aerators and drains may plug occasionally as old scale some recommendations for maximizing the benefits and your is removed from your plumbing system and water heater.
  • Page 7: Ordering Information

    Ordering Information OneFlow + Complete System ® 7100638 OFPSYS Scale Prevention and Water System OneFlow + Water Filter Replacement ® 7100639 OFPRFC Radial Flow Carbon Black Cartridge 7100640 OFPSP Scale Prevention Cartridge 7100641 OFPCOM Combo Pack FP14 OneFlow + System Replacement Parts ®...