Watts OneFlow OF744-10 Installation, Operation And Maintenance Manual

Watts OneFlow OF744-10 Installation, Operation And Maintenance Manual

Anti-scale system chemical-free, salt-free scale prevention
Hide thumbs Also See for OneFlow OF744-10:
Table of Contents

Advertisement

Available languages

Available languages

Installation, Operation and
Maintenance Manual
OneFlow
Anti-Scale System
®
Chemical-Free, Salt-Free Scale Prevention
Model OF744-10
Model OF844-12
!
WARNING
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
Introduction
The Watts OneFlow
Anti-Scale System provides protection
®
from scale formation on internal plumbing surfaces. The
OneFlow
system can be installed at the point of entry to a
®
building to treat both hot and cold water, or it can be located
directly before a water heater, boiler, or other water using
device that requires protection from hard water.
OneFlow
prevents scale by transforming the normal dissolved
®
hardness minerals into undissolved crystal microparticles.
These crystals stay suspended in the water and have a greatly
reduced ability to react and attach to surfaces like dissolved
hardness does. Therefore the problem of internal buildup
of scale in pipes, water heaters and on fixtures and glass is
greatly reduced.
OneFlow
is not a water softener or a chemical additive (like
®
anti-scalants or sequestrants). It is a scale prevention device
with proven third party laboratory test data and years of
successful residential and commercial installation. OneFlow®
is the one water treatment device that effectively provides scale
protection and is a great salt-free alternative to water softening
(ion exchange) or scale sequestering chemicals. Laundry and
warewashing chemistry will likewise require adjustments.
OneFlow
Benefits
®
• Chemical-free scale prevention and protection – converts
hardness minerals to harmless, inactive microscopic crystals
making OneFlow
an effective alternative technology to
®
a water softener for the prevention of scale due to water
hardness
• Virtually maintenance free - no control valve
• Uses environmentally friendly technology by using no salt
or other chemicals to constantly add, no electricity and no
wastewater
• Improves efficiency of all water using appliances – both hot**
and cold
• Simple sizing & installation – all you need to know is pipe
size and the peak flow rate.
Model OF948-16
Model OF1054-20
• Safe for landscaping and lawn watering. No need for costly
bypass plumbing.
• Compatible with all on-site and community wastewater
treatment systems.
• Perfect system for towns or communities where water
softeners are banned or restricted
• OneFlow
does not remove minerals or add sodium to the
®
water supply
• OneFlow can be installed as pre-treatment to commercial
reverse osmosis systems (contact your Watts Representative
for further details)
* For high-flow applications, contact your Watts Representative
for details on larger, multi-tank systems plumbed in parallel
that can meet high flow applications from 100 gpm to and
above 1000 gpm
** For hot water applications where feed water temperature is
100°F – 140°F (38° – 60°C), please consult ES-OneFlow-
HotWater.
Systems are certified through WQA
against NSF/ANSI Standards 61 and 372
for Lead Free compliance.
!
WARNING
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
IOM-OF744/844/948/1054

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OneFlow OF744-10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Watts OneFlow OF744-10

  • Page 1 * For high-flow applications, contact your Watts Representative for details on larger, multi-tank systems plumbed in parallel OneFlow is not a water softener or a chemical additive (like ®...
  • Page 2: Specifications

    OneFlow media. For applications with copper concentration greater than 1.3 ppm, please consult Watts Water Quality Technical Service. To NOTICE further minimize any problem with excess copper, avoid applying excessive flux on the inner surfaces of the pipe and use a low- Spotting May Occur on External Plumbing corrosivity water soluble flux listed under the ASTM B813 standard.
  • Page 3: Mechanical Specifications

    ASTMB813 standard. For applications with copper concentration greater than 1.3 ppm, please contact Watts Pure Water Technical Service at 1-800-224-1299. NOTICE...
  • Page 4: Installation

    Replacement Media Typical Connection Fittings Model Replacement Frequency OF744-10 Media should be replaced every 3 years OF844-12 Media should be replaced every 3 years OF948-16 Media should be replaced every 3 years OF1054-20 Media should be replaced every 3 years Installation Tighten the Tank Head “A”...
  • Page 5: Installation And Start-Up

    Bypass Valve Modification Service Position As shipped, the bypass down-flow tank. is set-up for down-flow use. The arrow shape of the handles points in the wrong direction for UP-flow use. To convert it to UP-flow use, pull up on the red handles until they come off.
  • Page 6: Replacing The Media

    Replacing the Media 16. Reconnect inlet and outlet union connections. NOTICE 17. If you have installed optional By-Pass CK-V3006 (EDP #0002167), place into Service position. Your OneFlow media should be replaced every (3) years. ® 18. Open the feed water inlet (slowly) to fill the tank. Shut off the primary feed supply going to the OneFlow ®...
  • Page 7: Limited Warranty

    7. Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made. 8. Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then current production.
  • Page 8 * Para las aplicaciones de alto flujo, comuníquese con su del sarro en las tuberías, los calentadores de agua, los accesorios representante de Watts para obtener más información sobre y el vidrio se reduce de manera significativa. sistemas multitanques más grandes conectados en paralelo que pueden alcanzar caudales de 100 gpm a 1000 gpm o más.
  • Page 9: Especificaciones

    1,3 ppm, póngase Pueden detectarse manchas en las en contacto con el Servicio técnico de calidad de Watts Water. Para minimizar aún más todo problema de exceso de cobre, evite superficies de las cañerías externas aplicar un flujo excesivo en las superficies internas de la cañería y...
  • Page 10: Especificaciones Mecánicas

    ASTM B813. Para aplicaciones que contengan concentraciones de cobre mayores a 1,3 ppm, póngase en contacto con el servicio técnico de Watts Pure Water al 1-800-224-1299. AV IS O ***Sílice La sustancia de OneFlow no reduce la formación de sílice.
  • Page 11: Instalación

    Regenerador de reemplazo Acoplamientos de conexión típicos Modelo Frecuencia de reemplazo Conjunto de latón soldado sin plomo Conjunto de latón soldado sin plomo de 3/4 in (2 cm)(LF = lead-free) de 1 in (2,5 cm) OF744-10 El regenerador debe reemplazarse cada 3 años OF844-12 El regenerador debe reemplazarse cada 3 años OF948-16...
  • Page 12: Instalación Y Puesta En Marcha

    Modificación de la válvula de derivación Tal como se envía, la Posición de servicio válvula de derivación está tanque de flujo configurada para el uso de descendente. flujo descendente. La forma de la flecha de las manijas apunta en dirección contraria para el uso de flujo ascendente.
  • Page 13 Reemplazo del regenerador Vuelva a conectar el ensamblaje del cabezal al tubo AV I S O distribuidor y enrosque el ensamblaje del cabeza de nuevo en el tanque. Ajuste el cabezal a mano hasta que la conexión El regenerador de OneFlow debe reemplazarse cada (3) años.
  • Page 14: Garantía Limitada

    7. Las piezas defectuosas están sujetas a una inspección por Watts Regulator Company o algún representante autorizado antes de realizar el ajuste de compromiso de garantía final. 8. Watts Regulator Company se reserva el derecho de realizar cambios o sustituciones en las piezas o equipos con material de calidad o valor equivalente y luego de su producción actual.
  • Page 15 OneFlow n’est pas un adoucisseur d’eau ni un additif chimique ® représentant Watts pour des systèmes plus importants à multiples (comme les agents antitartre ou séquestrants). Il s’agit d’un réservoirs, installés en parallèle, qui peuvent satisfaire aux dispositif de prévention de tartre avec des données de test applications à...
  • Page 16: Caractéristiques Techniques

    également applications dont la concentration de cuivre dépasse 1,3 ppm, des ajustements. veuillez communiquer avec l’équipe d’assistance technique Watts Water. Pour réduire davantage tout problème d’excès de cuivre, évitez d’appliquer trop de flux sur les surfaces intérieures des AV IS tuyaux et utilisez un flux soluble à...
  • Page 17: Spécifications Mécaniques

    à l’eau de faible corrosivité énuméré sous la norme ASTMB813. Pour des applications dont la concentration de cuivre dépasse 1,3 ppm, veuillez communiquer avec l’équipe d’assistance technique Watts Pure Water au 1-800-224-1299. AVIS ***Silice Le média OneFlow ne réduit pas le tartre de silice.
  • Page 18: Présentation Du Système

    Médium de rechange Raccords types Modèle Fréquence de remplacement Ensemble raccord en laiton Ensemble raccord en laiton LF 3/4 po (1,905 cm) LF 1 po (2,5 cm) OF744-10 Le médium doit être remplacé tous les 3 ans OF844-12 Le médium doit être remplacé tous les 3 ans OF948-16 Le médium doit être remplacé...
  • Page 19: Installation Et Démarrage

    Modification de la vanne de dérivation Réservoir à flux descendant La vanne de dérivation, en position de service. lorsqu’elle est livrée, est configurée pour une utilisation en flux descendant. La flèche des poignées pointe dans la mauvaise direction pour une utilisation en flux ascendant.
  • Page 20 Remplacement des médias Serrez la tête à la main jusqu’à ce que le raccordement soit AV IS serré. Reconnectez les raccords d’entrée et de sortie. Votre médium OneFlow doit être remplacé tous les 3 ans. ® Si vous avez installé la vanne de dérivation facultative modèle CK-V3006 (Nº...
  • Page 21: Garantie Limitée

    GARANTIE TACITE DE QUALITÉ MARCHANDE OU D’ADAPTATION À UN BUT PARTICULIER. Le recours décrit dans le premier paragraphe de cette garantie constitue le seul recours à toute violation de la présente garantie. Watts Regulator Company ne saurait être tenue responsable de tout dommage accessoire, spécial ou indirect, y compris, sans s’y limiter : la perte de profits ou le coût afférent à...

This manual is also suitable for:

Oneflow of948-16Oneflow of844-12Oneflow of1054-20

Table of Contents