BEFORE YOU BEGIN
BEFORE YOU BEGIN
·
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
·
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
·
These instructions contain important care, cleaning, and
warranty information -
consumer
.
·
Observe all local plumbing and building codes.
·
Carefully inspect the new urinal for damage.
·
Site preparation may require additional tools and
hardware.
·
Fixture dimensions are nominal and conform to tolerances
established by ASME Standards (A112.19.2-2018).
·
The product complies with GB/T 6952-2015.
CAUTION: Risk of personal injury or product
damage.
Handle with care. Vitreous china can break
or chip if the product is handled carelessly.
No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137
8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA
NO.1 KOHLER STREET, ECONOMIC DEVELOPMENT ZONE OF FAKU COUNTY, SHENYANG LIAONING PROVINCE, PRC
1356730-T01-B
TOUCHLESS FLOOR STANDING W/ELECTROLYZED WATER 1L/AC
TOUCHLESS FLOOR STANDING W/ELECTROLYZED WATER 3L/AC
TOUCHLESS FLOOR STANDING W/ELECTROLYZED WATER & IOT 1L/AC
please leave instructions for the
MODERN LIFE
TOUCHLESS FLOOR STANDING URINAL 3L
K-21842T(
·
·
·
·
·
·
·
2018)
·
GB/T 6952-2015
2
528137
8
256410
1
110400
©
Copyright Kohler China Investment Co., Ltd. 2019
-1-
©
INSTALLATION INSTRUCTIONS
)/K-21842T-C05(
(
K-21842T-WEW
(
K-21842T-EW
(
) (1L)
K-21842T-WXEW
ASME
(A112.19.2-
POST CODE:
256410
POST CODE:
(3L)
)
) (1L)
) (3L)
-
:
110400
2019

Advertisement

Table of Contents
loading

Summary of Contents for Kohler MODERN LIFE K-21842T

  • Page 1 Handle with care. Vitreous china can break or chip if the product is handled carelessly. No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137 528137 8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA...
  • Page 2: Specifications

    RECOMMENDED TOOLS AND MATERIALS (NOT SUPPLIED) RECOMMENDED TOOLS AND MATERIALS (NOT SUPPLIED) · · Open end/adjustable wrenches · · Tape measure · · Basin wrench · · Pipe wrench · · Square · · Level · · Pliers · · Socket wrench with sockets ·...
  • Page 3 · K-21842T-WXEW CMIIT ID:2018DP2230 ROUGHING-IN * Recommended dimensions for installation only, please adjust according to actual situation. Reference Value Unit:mm Supply 1008 150* 800* 545* Wall Floor Fig.1 Kohler reserves the right to change marked dimensions without prior notice. 1356730-T01-B...
  • Page 4: Prepare The Site

    Notice: To ensure an effective flush performance, 25mm strongly recommended inner diameter of water supply (including water meter, valve, ) 0.18MPa ~0.55MPa etc.) is no less than 25mm, and supplied water pressure (sensor inlet dynamic pressure) is 0.18MPa ~0.55MPa. PREPARE THE SITE PREPARE THE SITE NOTE: If a pre-existing waste pipe will be used and will result...
  • Page 5: Installation

    INSTALLATION Install and uninstall the sensor controller a. Install the sensor controller box. b. Install the screw. c. Connect the sensor wire. Install and uninstall the Fixture, Valve Assembly Unscrew the screws on the Fixture, Valve Assembly. Remove the Fixture, Valve Assembly from the urinal by moving it. Install DC Power Unit (17) (18)
  • Page 6 Power Connection K- 21842T 1. Please directly reference to install DC Power Unit when installing K- 21842T (DC). 2. Please match K-16305T-NA AC power unit when installing K-21842T-C05 K-16305T-NA K-21842T-C05. The way of installation is as below: CAUTION: 220V a. Do not connect 220V AC Power supply to DC wiring terminal.
  • Page 7 3. AC/DC Switch Power connect way (for K-21842T-WEW/K- (K-21842T-WEW/K-21842T-EW/K- 21842T-EW/K-21842T-WXEW) 21842T-WXEW Control Box Connector Switch Power Fig.6 Notice: a. Keep the connector away from water. b. Don't mistake the direction of inlet and outlet. c. Do not connect the DC output of AC power unit to AC power supply.
  • Page 8 2. Connect inlet pipe: Connect to the corner valve. 3. Install flange (see Fig.8, optional for purchase). Put the urinal against wall and align the bottom with the lines drawn. 4. Insert the screw through the screw hole (see Fig.9) Into the L-shaped fixing block.
  • Page 9: Maintenance

    Install fragrance porcelain (for K-21842T-WXEW only) K-21842T-WXEW) 1. Insert the scent top into the plug. 2. Take out the tube. Fill fragrance into the tube. Do not overfill to avoid overflow. 3. Insert the plug into the tube. 4. Insert the tube into the hole on the urinal cover.
  • Page 10: Troubleshooting

    TROUBLESHOOTING Please make following checks before repair: Symptoms Probable causes Corrective actions 1. No power or mistake connected. 1. Check the power connect. 2. Out of electricity. 2. Replace batteries. No flushing 3. Sensor no working. 3. Check connector connect or Replace sensor.
  • Page 11 (calcium hypochlorite) can seriously damage fittings in the urinal. This damage can cause leakage and property damage. Kohler Company shall not be responsible or liable for any damage to these urinal fittings caused by the use of cleaners containing chlorine (calcium hypochlorite).

Table of Contents