Download Print this page
Kohler MODERN LIFE K-21840T-2ER Installation Instructions Manual
Kohler MODERN LIFE K-21840T-2ER Installation Instructions Manual

Kohler MODERN LIFE K-21840T-2ER Installation Instructions Manual

Fl urinal rear 1l/2.5l

Advertisement

Quick Links

BEFORE YOU BEGIN
BEFORE YOU BEGIN
·
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
·
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
·
These instructions contain important care, cleaning, and
warranty information -
consumer
.
·
Observe all local plumbing and building codes.
·
Carefully inspect the new urinal for damage.
·
Site preparation may require additional tools and
hardware.
·
Fixture dimensions are nominal and conform to tolerances
established by ASME Standards (A112.19.2-2018).
·
The product complies with GB/T 6952-2015, GB 28377-
2019.
CAUTION: Risk of personal injury or product
damage.
Handle with care. Vitreous china can break
or chip if the product is handled carelessly.
ORDERING INFORMATION
MODERN LIFE FL Urinal (Rear) (1L/2.5L) .......K-21840T-2ER
RECOMMENDED TOOLS AND MATERIALS (NOT SUPPLIED)
RECOMMENDED TOOLS AND MATERIALS (NOT SUPPLIED)
·
Open end/adjustable wrenches
·
Tape measure
·
Basin wrench
·
Pipe wrench
·
Square
·
Level
·
Pliers
·
Socket wrench with sockets
·
Screw driver
·
Seal tape
·
Connection wire
·
Wire cutter
·
Insulation tape
·
Bushing
·
Drill
·
Sealant
No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137
8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA
NO.1 KOHLER STREET, ECONOMIC DEVELOPMENT ZONE OF FAKU COUNTY, SHENYANG LIAONING PROVINCE, PRC
1356499-T01-B
please leave instructions for the
MODERN LIFE
·
·
·
·
·
·
·
2018)
·
GB/T 6952-2015 GB 28377-2019
·
/
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
2
528137
8
256410
1
110400
©
Copyright Kohler China Investment Co., Ltd. 2020
-1-
©
INSTALLATION INSTRUCTIONS
FL URINAL (REAR) (1L/2.5L)
(
K-21840T-2ER
ASME
(A112.19.2-
(
) (1L/2.5L)......K-21840T-2ER
(
)
POST CODE:
256410
POST CODE:
) (1L/2.5L)
-
:
110400
2020

Advertisement

loading
Need help?

Need help?

Do you have a question about the MODERN LIFE K-21840T-2ER and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kohler MODERN LIFE K-21840T-2ER

  • Page 1 · · Drill · · Sealant No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137 528137 8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA POST CODE: 256410 256410 NO.1 KOHLER STREET, ECONOMIC DEVELOPMENT ZONE OF FAKU COUNTY, SHENYANG LIAONING PROVINCE, PRC...
  • Page 2 150* 800* 545* Wall Floor Fig.1 Kohler reserves the right to change marked dimensions without prior notice. Notice: To ensure an effective flush performance, 25mm strongly recommended inner diameter of ) 0.18MPa ~0.55MPa water supply (including water meter, valve, etc.) is no less than 25mm, and supplied water pressure (sensor inlet dynamic pressure) is 0.18MPa ~0.55MPa.
  • Page 3: Prepare The Site

    PREPARE THE SITE PREPARE THE SITE NOTE: If a pre-existing waste pipe will be used and will result in an acceptable rim height (refer to the rough-in dimensions), follow the retrofit installation instructions. For Retrofit Installations Turn the water supply line off, remove the existing urinal, then cap off the water supply line inside the wall.
  • Page 4 B. Install urinal 1. Check the regulator, see Fig.3. Back of Urinal Regulator Nozzle Fig.3 2. Connect inlet pipe: connect the inlet pipe to the sensor(the inlet pipe can be purchased according to the actual position of the sensor). 3. Install flange (see Fig.4, optional for purchase). Put the urinal against wall and align the bottom with the lines drawn.
  • Page 5 C. Install Urinal Cover See Fig.#6 1. Open urinal cover lock package and remove contents. Fix hook and screw as shown. 2. Put urinal cover on the urinal. 3. Use supplied locking tool to install and tighten the screw. 4. Check that the urinal cover is properly locked. NOTE: Using a 5/8"...
  • Page 6: Important Consumer Information

    (calcium hypochlorite) can seriously damage fittings in the urinal. This damage can cause leakage and property damage. Kohler Company shall not be responsible or liable for any damage to these urinal fittings caused by the use of cleaners containing chlorine (calcium hypochlorite).

This manual is also suitable for:

Modern life k-21840t-er-0Modern life k-21840t-2er-0