2.4 Controller-to-Terminal Distance Limitations

The IBM controller has a timeout value after trans-
mitting a message to a terminal. If the response
from the terminal is not received within this
timeout, the controller ignores it and sends the
message to the next terminal.
2.4.1 D
C
ELAY
ALCULATIONS FOR
The round-trip propagation time is equal to twice
the time it takes the signal to travel from the
controller (T c ) through segments X1, X2, X3,
and X4, and through multiplexers T1, T2, and T3,
plus terminal response time (see Figure 2-5).
Maximum cable length is calculated as follows:
X1+X2+X3+X4 = [Controller Timeout-
(Tc+T1+T2+T3+Terminal Delay)] x Signal
Propagation ÷ 2.
T
X
c
1
3174
Controller
or
3274
(with RPQ 9901)
0 - 7
8 - 15
16 - 23
24 - 31
C
1
ONFIGURATION
T
X
1
2
MX330A-C
Copper
F/O
Figure 2-5. Delay Calculations for Configuration 1.
When:
Controller Timeout = 3174 - 50 µsec
Data Rate = 424 nsec/bit
T c (Controller Delay Time =
3174 - 3.5µsec (8-bit start sequence)
3274 - 24µsec (24-bit + 32-bit data stream)
T1 (MX330A-C Delay time) =
8-bit inbound, 8-bit outbound (6.78 µsec)
T2 (MX330A-D Delay time) =
16-bit inbound, 8-bit outbound (10.1 µsec)
T3 (Multiplexor Delay time) =
16-bit inbound, 8-bit outbound (10.1 µsec)
Terminal Delay (IBM max.) = 5.5 µsec.
Signal Propagation = 200 m/µsec
Applications using cable exceeding the maximum
calculated length require changing the controller
timeout. Timeout can be increased to 98 µsec or
200 µsec using an RPQ diskette, which can be
ordered from IBM.
T
X
2
3
Multiplexer
MX330A-D
0 - 7
8 - 15
16 - 23
24 - 31
Multiplexer
CHAPTER 2: Introduction
3274 - 56 µsec
T
X
3
4
8-Port
0
1
7
0
1
7
8-Port
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx330a-dMx330a-c

Table of Contents