Valve, Pump Relay and Sensor Installation

Figure 13
1
2
Step 1
– Route valve wires from the valves, master valves, pump relay and/or sensor into the controller cabinet.
Note: 18 AWG (1.0 mm
and is color-coded to simplify installation. It can be routed directly into the controller through the access hole provided for
valve wire conduit (if conduit is not used).
Step 2
to one wire from each valve solenoid and/or pump relay. (Either of the two wires from the solenoid or pump relay can be used
for this connection.) This connection will be designated as the valve common wire.
Connect a separate cable wire to the remaining wire from each valve solenoid. Note the wire color-code used for each valve and
the zone it controls. You will need this information when connecting the valve wires to the controller.
sensor wires for installation.
Step 3
– Secure all wire splices using wire nut connectors. To prevent corrosion and possible short circuits, always use an insulated wire
nut, grease cap or similar waterproofing method.
Step 4
Secure the individual valve wires to the appropriate zones they control, Zone 1 valve to terminal 1, Zone 2 valve to terminal 2, etc.
terminals labeled COM. Secure the Master Valve or Pump Relay wire to the terminal labeled
To prevent controller damage, do not connect the pump motor starter directly to the controller.
to the sensor terminals. Refer to the provided sensor instructions for further installation instructions.
Step 5
– Test for proper operation.
8
COM
2
) multi-wire sprinkler valve connection cable can be used. This cable is insulated for direct burial
- Connect any two unused color-coded wires to the sensor. Note the color-code of the
- Secure the valve common wire (white) to either of the two terminals labeled COM.
- Remove the jumper wire from the SENSORS terminals. Secure the two sensor wires
SENSOR
SENSOR
MV
COM
- Connect the white color-coded wire from the cable
- Secure the valve common wire (white) to either of the two
PUMP
.