Olympus ESG-150 Quick Reference Manual

Olympus ESG-150 Quick Reference Manual

Electrosurgical generator

Advertisement

Quick Links

ESG-150
( Electrosurgical Generator)
Quick Reference Guide
CAUTION:
This guide is only a summary of the instructions for use of the ESG-150 Electrosurgery Generator. Be sure to reference the instruction
manual that was included with your product purchase.
ESG-150 Electrosurgical Generator
Bipolar
Neutral
On/Off
Monopolar
ESG-150 User Flexibility
Basic Level
Advanced Level
Graphical
User
Interface
CONTINUED ON NEXT PAGE

Advertisement

loading

Summary of Contents for Olympus ESG-150

  • Page 1 ( Electrosurgical Generator) Quick Reference Guide CAUTION: This guide is only a summary of the instructions for use of the ESG-150 Electrosurgery Generator. Be sure to reference the instruction manual that was included with your product purchase. ESG-150 Electrosurgical Generator...
  • Page 2 ESG-150 ( Electrosurgical Generator) Quick Reference Guide Monopolar Home Screen Basic Level Advanced Level Active Socket Contact Quality Monitor Active Socket Contact Quality Monitor Active Mode Power Adjustment Effect Level Adjustment Change Output Socket System Setup Change Output Socket System Setup...
  • Page 3 ESG-150 ( Electrosurgical Generator) Quick Reference Guide ESG-150 System Operating Steps Turn on the ESG-150. Select Basic or Advanced Level Functionality. 1) Select the “Menu” button. 2) Select “User Level”. 3) Select “Basic” or “Advanced” Functionality. 4) Select the “OK” button to confirm.
  • Page 4 ESG-150 ( Electrosurgical Generator) Quick Reference Guide ESG-150 System Operating Steps Select Mode: Monopolar; Bipolar. 1) Select the mode by tapping on the desired mode located on the bottom of the touch screen. (Optional) Select User Defined Settings. 1) Select the “Menu”.
  • Page 5 Changing the Power Level. Select to adjust power level. Changing the Effect. Select to adjust effect. (Effect is only available in the Advanced Level Function.) 1) Apply the neutral electrode to the patient. 2) Connect to the ESG-150. CONTINUED ON NEXT PAGE...
  • Page 6 ESG-150 ( Electrosurgical Generator) Quick Reference Guide ESG-150 System Operating Steps Monitor Neutral Electrodes: Contact Quality Monitor. If the red neutral electrode lights up and alarm tone sounds: • Is the neutral electrode correctly connected to the device? • Does the neutral electrode have...
  • Page 7 ESG-150 ( Electrosurgical Generator) Quick Reference Guide Creating User Defined Settings STEP 1 On the home screen Select Preferred Modes Select Power Level Select Effect Level Select Menu STEP 2 STEP 3 STEP 4 Settings/Setup Screen Save Setting Screen The setting will appear on the upper right of the touchscreen.
  • Page 8 Due to the heterogeneity of instruments and clinical conditions, Olympus cannot accept liability for clinical risks arising from the use of these example settings.
  • Page 9 • Yellow cut pedal to activate the selected cutting mode. • Blue coagulation pedal to activate the selected coagulation mode. • Foot switch plug (7-pin connector) to connect the foot switch with the ESG-150. The length of the connecting cable is 4m. YELLOW PEDAL...