Step 3- Convert Valves For Lp Gas - Thermador Masterpiece Series Installation Manual

Gas cooktop lp conversion kit
Hide thumbs Also See for Masterpiece Series:
Table of Contents

Advertisement

Available languages

Available languages

Insert each of the LP gas venturis provided with this
8.
kit. Tighten snugly.
Replace burners, burner caps and grates.
9.
Continue to Step 3.
10.
Reinstall venturis from Step 2, part 3. Continue to
11.
Step 3.
Notes
Venturis must go back in to the same position as
shipped from the factory. The diagram below may
be used as a reference.
The venturis are identified by grooves running
around the lower section. The below image shows
the correct venturi placement with their
corresponding burners. It is very important to install
the correct venturi size for each burner.
Model SGSP and SGSXP LP Venturis
8

Step 3- Convert Valves for LP gas

The bypass jet on each valve must be adjusted.
Turn all knobs to the "OFF" position.
1.
Remove knobs.
2.
Locate the correct point of insertion for the long, thin
3.
flat blade screwdriver to adjust the bypass jet (see the
following illustration).
Insert a long, thin flat blade screwdriver in the hollow
stem of the valve. The adjustment screw is
approximately 1
" (39 mm) from the top of the stem.
^
The screwdriver slides through a thin rubber barrier in
the stem (helps prevent damage in the case of a spill
on the unit surface).
Engage the tip of the screwdriver into the adjustment
4.
screw by slowly turning the screwdriver and feeling for
the blade to engage the screw. Then turn the screw
clockwise about 70 degrees (less than 1/4 turn) until it
"bottoms out" (does not turn any further). The screw
does not take much force to turn. Once the screw
does not turn any further, stop. Do not overtighten.
Repeat for each valve until all have been adjusted
correctly.
Replace the knobs.