18. [Response Time] (Command: m g)
▶ Controls the Response Time.
Transmission [m][g][ ][Set ID][ ][Data][Cr]
Data 00 : [Faster]
02 : [Normal]
Ack [g][ ][Set ID][ ][OK/NG][Data][x]
19. [Black Stabilizer] (Command: m h)
▶ Controls the Black Sharpness Optimization function.
Transmission [m][h][ ][Set ID][ ][Data][Cr]
Data Min : 00 - Max : 64
Ack [h][ ][Set ID][ ][OK/NG][Data][x]
20. [Uniformity] (Command: m i)
▶ Controls the Uniformity function.
Transmission [m][i][ ][Set ID][ ][Data][Cr]
Data 00 : [On]
Ack [i][ ][Set ID][ ][OK/NG][Data][x]
46
01 : [Fast]
03 : [Off]
01 : [Off]
21. [Gamma] (Command: m j)
▶ Adjusts the Gamma settings.
Transmission [m][j][ ][Set ID][ ][Data][Cr]
Data 00 : [Gamma 1.8]
02 : [Gamma 2.2]
04 : [Gamma 2.6]
Ack [j][ ][Set ID][ ][OK/NG][Data][x]
22. [Color Temp] (Command: k u)
▶ Adjusts the colour Temp.
Transmission [k][u][ ][Set ID][ ][Data][Cr]
Data
00 : [Custom]
02 : [7500K]
04 : [Manual]
Ack [u][ ][Set ID][ ][OK/NG][Data][x]
23. Red Gain (Command: j w)
▶ Adjusts the red.
Transmission [j][w][ ][Set ID][ ][Data][Cr]
Data Min : 00 - Max : 64
Ack [w][ ][Set ID][ ][OK/NG][Data][x]
01 : [Gamma 2.0]
03 : [Gamma 2.4]
05 : [DICOM Gamma Curve]
01 : [6500K]
03 : [9300K]