3 Assembly and installation
3.1
Installation location requirements
Certain ambient conditions must be complied with
Connecting cables for connecting the various components must be present
In the event of wall mounting: The wall must be able to bear the weight of the sheet steel housing
In the event of mounting on a top hat rail: The top hat rail must be of type "TS 35" in accordance with
EN 50022
The customer-provided power supply must have a separate power circuit
The voltage of the customer-provided power supply must fulfil the requirements of the power supply
that is used. See power supply operating instructions for more information.
The cable of the customer provided power supply must be 2.5 mm thick
3.2
Assembly and installation of controller and power supply on top hat rail
The controller can be connected to any power supply that fulfils the following requirements:
-
12–24 V DC output voltage
-
Wattage: depending on system configuration (min. 11 W)
WARNING!
Risk of fire!
If the external power supply has wattage of more than 60 W, there is a risk of fire if it is installed on
a top hat rail.
-
In this case, install power supply in a separate sheet steel housing.
Assembly and installation
Chapter 5 "Technical data" on page 43
25