B.Well WF-1000 Instructions For Use Manual

B.Well WF-1000 Instructions For Use Manual

Infrared ear/forehead thermometer

Advertisement

Instructions for use
WF-1000
Infrared Ear/Forehead
Thermometer
EN

Advertisement

Table of Contents
loading

Summary of Contents for B.Well WF-1000

  • Page 1 Instructions for use WF-1000 Infrared Ear/Forehead Thermometer...
  • Page 3: Table Of Contents

    Instructions for use WF-1000 INFRARED EAR/FOREHEAD THERMOMETER MODEL: WF-1000 INSTRUCTIONS FOR USE Index 1. Introduction ....................4 2. Intended purpose ...................5 3. Precautions....................5 4. Contraindications ...................6 5. Product identification ................7 6. Description of LCD display ..............8 7. What is a “normal” temperature? ............9 8.
  • Page 4: Introduction

    Dear consumer! We congratulate you with a B.Well infrared thermometer buying! Thank you for choosing our product! Product was designed, verifi ed and supervised by B.Well Swiss AG, Switzerland. Applied Swiss control system assures high quality endurance and safety of all B.Well products.
  • Page 5: Intended Purpose

    Instructions for use WF-1000 6) Auto power off for power saving. 7) Low-battery indicator, warning indication for measuring range. It is so convenient and easy. 2. INTENDED PURPOSE Infrared thermometers are used for measuring body tem- perature by measuring the heat generated by the eardrum or the surface skin of the forehead.
  • Page 6: Contraindications

    Instructions for use WF-1000 should stay in steady state room condition for at least 30 minutes. 9. Avoid measuring temperature in 30 minutes after exer- cise, bathing, or returning from outdoor. 10. To protect the environment, dispose of empty batteries at appropriate collection sites according to national or local regulations.
  • Page 7: Product Identification

    Instructions for use WF-1000 5. PRODUCT IDENTIFICATION Forehead / Cover cap Power / Scan button Probe tip Battery compartment...
  • Page 8: Description Of Lcd Display

    Instructions for use WF-1000 6. DESCRIPTION OF LCD DISPLAY Measurement display °C or °F Celsius Scale or Fahrenheit Scale “Measurement in progress” symbol Battery warning symbol Last memorized Forehead Scan Mode Ear Scan Mode Object Scan Mode Temperature Display Error...
  • Page 9: What Is A "Normal" Temperature

    Instructions for use WF-1000 7. WHAT IS A “NORMAL” TEMPERATURE? Although the generally accepted “normal” temperature reading is 36.6˚C, temperature readings can vary from 35.2˚C to 36.8˚C and still may be considered “normal”. Variations in temperature can be attributed to activities such as exercise, smoking, eating and drinking.
  • Page 10 Instructions for use WF-1000 the age of 6 months. In infants under 6 months, the ear canal is still very narrow so the temperature of the ear- drum often cannot be recorded and the result displayed is often too low.
  • Page 11: How To Take Your Temperature

    Instructions for use WF-1000 8. HOW TO TAKE YOUR TEMPERATURE To switch from ear scan mode to forehead scan mode, simply take off the Cover cap. To switch from forehead scan mode to ear scan mode, put on the Cover cap again. It is recommended to use your thumb to pull from either side of the Cover cap to remove it easily.
  • Page 12 Instructions for use WF-1000 This is important so that the sensor tip can be pointed directly at the eardrum. 3) Insert the sensor tip into ear canal carefully and then press the Power/Scan button for 1 second and release. 4) The end of the measuring time is signaled with a short beep and the measured value appears on the display.
  • Page 13 Instructions for use WF-1000 4) Release the button. The end of the measuring time is sig- nalled with a short beep and the measured value appears on the display. The screen displays “Lo” or “Hi” when the temperature measured is out of the measurement range. (See Figure 1,...
  • Page 14: Cleaning Instructions

    Instructions for use WF-1000 To ensure a long battery life, this thermometer will be automatically power-off after every one minute idling. Measuring the temperature of air, water surface, and items: Make sure the cap is on the thermometer. Turn on the thermometer.
  • Page 15: Battery Replacement

    Instructions for use WF-1000 10. BATTERY REPLACEMENT The low battery symbol will be shown at the lower part of the screen during the low battery power. Replace the battery as soon as possible. However, you may continue to use it (see Figure 6).
  • Page 16 Instructions for use WF-1000 3. Replace with a lithium 3V CR2032 battery in designated area. The larger part of the battery should be facing up. You should still be able to see the “+” sign when battery is installed. 4. Slide the cover back on. Unit is ready for immediate use Dispose of used batteries in accordance with the applicable legal regulations.
  • Page 17: Troubleshooting

    Instructions for use WF-1000 NOTE: Please keep the battery away from children. Do not store the battery at a high temperature. It is recommended to remove the batteries if the unit will not be used for an extended period of time.
  • Page 18: Applied Standards

    Instructions for use WF-1000 LCD Display Cause Solution The temperature mea- Operate the thermometer sured is higher than only between the specifi ed 50°C (122°F) temperature ranges. If nec- essary, clean the sensor tip. In the event of a repeated...
  • Page 19: Product Specifications

    Instructions for use WF-1000 • ISO 80601-2-56 Medical electrical equipment – Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement • IEC/EN 60601-1 Medical electrical equipment – Part 1: General requirement for safety •...
  • Page 20: Thermometer Set

    Instructions for use WF-1000 Weight ~ 51g (with batteries) Dimensions ~ 110 × 34 × 50mm (W × D × H) Additional Features 1. POST (Power-On-Self-Test) 2. Scanning Mode: Continuous scanning, automatic latch of maximum temperature reading. 3. Out of operating temperature (Lo/HI) Indication.
  • Page 21: Electromagnetic Compatibility Information

    Guidance and manufacturer’s declaration – еlectromagnetic emissions The WF-1000 Thermometer is intended for use in the electromagnetic enviroment specifi c below. The customer or the user of the WF-1000 Thermometer should assure that it is used in such an enviroment. Electromagnetic...
  • Page 22 Guidance and manufacturer’s declaration – еlectromagnetic immunity The WF-1000 Thermometer is intended for use in the electromagnetic enviroment specifi c below. The customer or the user of the WF-1000 Thermometer should assure that it is used in such an enviroment. Immunity...
  • Page 23 To assess the electromagnetic environment due to fi xed RF transmitters, an electromagnetic site survey should be considered. If the measured fi eld strength in the location in which the WF-1000 Thermometer is used exceeds the applicable RF compliance level above, the WF-1000 Thermometer should be observed to verify normal operation.
  • Page 24 RF communications equipment and the WF-1000 Thermometer The WF-1000 Thermometer is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the WF-1000 Thermometer can help prevent electromagnetic interference by maintaining a...
  • Page 25: Warranty

    Instructions for use WF-1000 17. WARRANTY Warranty period is 2 years from the date of purchase. This warranty doesn’t cover any damages caused by improper us- ing, and also battery, protective cover and packaging. When a manufacturing defect is revealed during the warranty period a faulty unit would be repaired or, if repairing is impossible, replaced with another one.
  • Page 26: Symbol Information

    Instructions for use WF-1000 18. SYMBOL INFORMATION Follow instructions before use Housing Ingress Protection rate: IP 22 (Protected from the penetration of solid bodies with dimension greater than 12.5 mm. Protected from the penetration of vertically falling water drops). Manufacturer’s Name...
  • Page 28 B.Well Swiss AG Bahnhofstrasse 24, 9443 Widnau, Switzerland www.bwell-swiss.ch...