CLEANING INSTRUCTIONS
CAUTION:
CUT HAZARD
Turn power switch OFF and
disconnect unit from electric
power before cleaning.
CAUTION:
CUT HAZARD
Impeller blades are sharp.
DO NOT operate the unit
unless the cover is properly
installed.
Use care when cleaning the
impeller.
CAUTION:
POWER
WASHING
DO NOT expose the motor to
any amount of water. Doing
so can damage the unit and is
not covered under warranty.
PREPARATION
FREQUENCY
TOOLS
CLEANING
1. Turn power switch OFF and unplug unit. Drain wash tank.
2. Remove cover. Store thumb screws for later use.
3. Using brushes, clean in, around and behind impeller.
Remove any mop strings or other fibers from impeller shaft.
4. Clean all accessible areas of the pump housing.
5. Check impeller for free rotation. Reassemble cover.
6. Wipe motor, power switch and power cord with a soft cloth
dampened with clean water.
7. Plug unit into receptacle.
Procedure is complete.
COVER
THUMB SCREW
8
Turn power switch OFF
Unplug from electrical power
Drain wash tank
Daily, or as needed
Bottle Brush, Soft Bristle Brush
Soft Cloth or Sponge
HOUSING
IMPELLER
IL1809