5 Maintenance

5.1 Daily

Keep the lift clean. Make sure power is cut off
before cleaning the lift.
Keep the working area clean. Excessive dust
in the work area will shorten the lifespan of the
lift.
Before operation, inspect and keep all the safety
devices of lift in order. If any problems are
found, adjust, maintain or replace the parts
timely.
Make sure that the pits are kept dry and clean.
Inspect if there is leakage in the air valve and if
it is well-lubricated.

5.2 Monthly

Refasten the anchor bolts.
Check all the hoses and fittings for possible
wearing and leakage. If any leakage is found
to be caused by worn sealing parts, replace with
parts meeting the specifications.
Check if the roller slide is well-lubricated with
high-quality #2 lithium lubricant.
Apply #2 lithium lubricant on a monthly basis

5.3 Every Six Month

Check all the moving parts for possible wearing,
interference and damage.
Inspect the lubrication of all the rollers. If the
roller is dragged along in lifting or lowering,
apply lubricant to the roller shaft.
At the end of the first six months, clean the
hydraulic system and replace the hydraulic oil.
Replace the hydraulic oil with N32 hydraulic oil
in winter and N46 in summer.
TLT830WA USER'S MANUAL
6 Storage and

Scrapping

6.1 Storage

When the lift needs to be stored for a long time:
Unplug from power socket.
Lubricate all the parts, including all the contact
surface of the rollers.
Bleed oil from tanks.
Cover the lift with plastic hood.
6.2 Scrapping
When the lift has exceeded its lifespan and can not be
used any more, disconnect it from the electrical supply
and dispose of as required by the local regulations.