COMBUSTION ADJUSTMENTS

G20
CO2 emission
%
Gas Consumption
m³/h
Flue gas mass flow
g/sec.
10.1

EMISSION SETPOINTS

ALUBOX X-treme boilers are offer to sale after all required
combusiton, efficiency and safety controls. Emission settings
mustn't be changed which are made by GASSERO. However, if
there is a deviation in the values which are given below, emission
settings should be changed by GASSERO authorized service.
ALUBOX
ALUBOX
X-TREME 350
X-TREME 430
min.
max.
min.
max.
9,11
9,16
9,16
9,15
6,93
35,23
8,84
44,6
31
154
40
These combution settings mentioned below must
be issued by authorized GASSERO services.
Flue gas analyzer must be used during to the
combustion adjustments.
ALUBOX
X-TREME 535
X-TREME 640
min.
max.
min.
8,69
8,91
8,83
10,75
53,47
8,45
201
47
238
ALUBOX X-treme MODEL BOILERS ARE DESIGNED
TO WORK ONLY WITH NATURAL GAS.
THEY CANNOT BE USED WITH LPG.
39
ALUBOX
ALUBOX
X-TREME LX 700
max.
min.
max.
9,13
8,91
9,09
64,52
12,09
69,82
39
271
54
308
ALUBOX
X-TREME 710
min.
max.
8,95
9,07
13,99
71,78
63
314