Alemite 9660-A Service Manual

Medium-pressure stationary pump

Advertisement

Medium-Pressure Stationary Pump

Description

The major components of the stationary pump assembly in
the 9660 model series consist of a(n):
• air-operated motor
• double-acting reciprocating pump tube
• extension
• bung adapter (Models 9660, 9669-B)
• drum cover assembly (Model 9660-A)
The medium-pressure (5:1 ratio) pump included with the
assembly is designed to deliver all grades of oil directly from
their original containers.
Models 9660, 9660-A, and 9669-B
Models 9660 and 9660-A include an extension to
accommodate 16-gallon containers. These models differ in their
accessories. Model 9669-B includes a bung adapter and an
extension to fit 55-gallon (200/205 liter) containers.
See Figure 1 .
Specifications
Air Motor
Piston Diameter x Stroke
Inches
Millimeters
2-15/16 x 3
74.6 x 76.2
For information on the air motor, refer to Service Guide SER 338066-A1
Pump Tube
Max. Material
Pressure
Material
Material
Inlet
Outlet
psi
1-1/2 " NPTF 1/2 " NPTF
750
* For detailed information, refer to Figure 3
Table 1 9660 Model Series Specifications
This document contains confidential information that is the property of Alemite Corporation
670729
and is not to be copied, used, or disclosed to others without express written permission.
Service Guide
Max. Air Pressure
Air Inlet
psi
1/4 " NPTF (f)
150
Delivery/Minute
Displacement
(Approximate)*
per Cycle
3
Bars Gallons
Liters
In
52
7
26.5
7.2
Alemite Corporation
PO Box 473515, Charlotte, North Carolina 28247-3515
©
Copyright
1997 by Alemite Corporation
Air Exhaust
Material
Outlet
Bung
Adapter
Bars
10.3
Extension
Container
Pump
Model
Gallons Liters
3
Cm
9660
16
118
9660-A
9669-B
55
Figure 1 Medium-Pressure Stationary Pump
Models 9660, 9660-A and 9669-B - Model 9660 Shown
9660
9660-A
9669-B
Air Inlet
(41.3 cm)
5-1/4 "
(13.3 cm)
Material Inlet
Extension
Bung
Adapter Cover
Inches
Cm
_
21-3/4
55.2
200/205 28-1/4
71.8
SER 9660
Revision (1-97)
16-1/4 "

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9660-A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alemite 9660-A

  • Page 1: Pump Assembly

    PO Box 473515, Charlotte, North Carolina 28247-3515 © Copyright 1997 by Alemite Corporation SER 9660 This document contains confidential information that is the property of Alemite Corporation 670729 Revision (1-97) and is not to be copied, used, or disclosed to others without express written permission.
  • Page 2 SER 9660 Medium-Pressure Stationary Pump Apply Thread Sealant Here Apply Thread Sealant Here Figure 2 Medium-Pressure Stationary Pump Models 9660, 9660-A, and 9669-B- Exploded View Revision (1-97) Alemite Corporation...
  • Page 3 5. Attach Air Coupler ( 4 ) to the Connector. Pump Assembly NOTE : The remaining procedures are appli- cable to model 9660-A only. IMPORTANT: Make sure to remove the pro- tective cover from the inlet of Pump Assem- 6. Fit the pump and cover assembly onto the container.
  • Page 4 SER 9660 Medium-Pressure Stationary Pump Revision (1-97) Alemite Corporation...

This manual is also suitable for:

9669-b9660

Table of Contents