Allen-Bradley PowerFlex Active Front End Installation Instructions Manual
Allen-Bradley PowerFlex Active Front End Installation Instructions Manual

Allen-Bradley PowerFlex Active Front End Installation Instructions Manual

In ip20 2500 mcc style enclosure frame 13 right-side bus splice kit

Advertisement

Installation Instructions

PowerFlex Active Front End in IP20 2500 MCC Style Enclosure
Frame 13 Right-Side Bus Splice Kit
Catalog Number
SK-Y1-BUSSPLICE-F13R (for use on only enclosure right side)
(1)
Electrical Rating
3000 Amps
Compatible Products
PowerFlex Active Front End Frame 13 in IP20 2500 MCC Style enclosure
(Catalog Nos. 20YD1K3P..., 20YD1K3W..., 20YF1K0P..., and 20YF1K0W...)
(2)
Certification
(1) For MCC bus splices.
(2) PowerFlex Active Front End UL listed up to 1469 amps DC.
This bus splice kit must be used with barrier kit SK-Y1-MCCBARRIER.

Additional Resources

Publication 20Y-IN004A-EN-P - October 2014
Topic
Page
Additional Resources
1
2
2
3
These documents contain more information on related products from Rockwell
Automation.
Resource
PowerFlex Active Front End User Manual, publication
20Y-UM001
PowerFlex Active Front End—Frame 13 Hardware
Service Manual, publication 20Y-TG002
You can view or download publications at
www.rockwellautomation.com/literature/. To order paper copies of technical
documentation, contact your local Allen-Bradley distributor or Rockwell
Automation sales representative.
Description
Provides installation, wiring, operating, and
troubleshooting information.
Provides Frame 13 hardware service information and
schematic diagrams.
http://

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PowerFlex Active Front End and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Allen-Bradley PowerFlex Active Front End

  • Page 1: Installation Instructions

    SK-Y1-BUSSPLICE-F13R (for use on only enclosure right side) Electrical Rating 3000 Amps Compatible Products PowerFlex Active Front End Frame 13 in IP20 2500 MCC Style enclosure (Catalog Nos. 20YD1K3P…, 20YD1K3W…, 20YF1K0P…, and 20YF1K0W…) Certification (1) For MCC bus splices. (2) PowerFlex Active Front End UL listed up to 1469 amps DC.
  • Page 2 PowerFlex Active Front End in IP20 2500 MCC Style Enclosure Frame 13 Right-Side Bus Splice Kit ATTENTION: To avoid an electric shock hazard, verify that the voltage on the bus capacitors has discharged completely before performing any work on the Active Front End.
  • Page 3 PowerFlex Active Front End in IP20 2500 MCC Style Enclosure Frame 13 Right-Side Bus Splice Kit Right-side Connection To connect the bus bars and attach an enclosure to the right side of the AFE enclosure, follow these steps. Step 1: Remove power from the AFE.
  • Page 4 PowerFlex Active Front End in IP20 2500 MCC Style Enclosure Frame 13 Right-Side Bus Splice Kit Step 4: Connect the MCC bus and PE ground splices to the AFE bus and ground bars, respectively. Flat Washer Bus Clamp Assembly M-353...
  • Page 5 PowerFlex Active Front End in IP20 2500 MCC Style Enclosure Frame 13 Right-Side Bus Splice Kit Step 5: Attach both enclosures using the air barrier panels and hardware supplied in the barrier kit (catalog number SK-Y1-MCCBARRIER). ATTENTION: The barrier kit must be used between the enclosures being attached together to maintain proper air flow within each individual enclosure.
  • Page 6 PowerFlex Active Front End in IP20 2500 MCC Style Enclosure Frame 13 Right-Side Bus Splice Kit Step 6: Connect the MCC bus and PE ground splices in the AFE enclosure to the bus and ground bars, respectively, in the other enclosure.

Table of Contents