1 General safety information Specified normal use The drive unit is intended for horizontally operating sliding doors. The safe operation is only guaranteed with specified normal use. The drive unit is to be protected from rain, moisture and aggressive ambient conditions. No liability for damage caused by other applications or non-observance of the information in the manual.
2 Technical Data Type SG 85R Output torque Output speed Output shaft / hollow shaft 40,00 Maximum output speed open / close 42 / 42 for frequency inverter operation Maximum door weight 16000 Supply voltage 3N~ 400 Operating current 1,80 Operating frequency Power factor cos φ...
3 Mechanical installation Prerequisites The permissible loads on walls, fastenings, mountings and transmission elements must not be exceeded, even for maximum holding torques or locking torques (▶ refer to technical data). Connection elements ▶ Self-locking connection ▶ Utilize the hole diameter ▶...
Page 7
Mounting Four holes are provided for mounting. BAGAD0 3 3 0 1 _Z0 0 2...
Page 8
Installation The descriptions below apply to general door specifications. The specifications of the door manufacturer must also be observed during installation. Warning - Potential injury or danger to life! During installation, be sure to use a lifting device that has a sufficient load- carrying capacity.
Page 9
Warning - Potential injury or danger to life! Disconnect the electric supply to set the friction clutch. The friction clutch provides overload BAGAE3 3 0 3 _Z0 0 2 protection. It is tightened finger-tight at the factory. Turning to the right (handwheel or screw) increases the transferable torque.
4 Electrical installation Warning - Danger to life from electric current! Switch the mains OFF and check that the cables are de-energised Observe the applicable regulations and standards Make the electrical connection according to standard Use suitable tools Performing electrical installation Remove the cover.
7 Completing commissioning / inspection Check the following components and then install all covers. Gearbox Check the drive unit for loss of oil (a few drops can be neglected). Protect the output-shaft permanently against corrosion. Mounting Check that all connection elements (consoles, torque mounts, screws, locking rings, etc.) are secure and in proper condition.
Page 13
Brake Warning - Potential injury or danger to life! Carry out a brake test. Overrun depends on the door and its equipment. The specifications of the door manufacturer must be observed. In an environment that can affect the coefficient of friction of the brake pad (atmosphere with oil, solvents, detergents, etc.), class of protection IP65i must be adopted.
EMC Directive 2014/30/EU within the meaning of RoHS Directive 2011/65/EU The following requirements from Appendix I of GfA ELEKTROMATEN GmbH & Co. KG the Machinery Directive 2006/42/EC are met: declare under our sole responsibility that the 1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2,...