United Spa Controls C5 Series Installation Manual & Users Manual page 28

Spa controls
Table of Contents

Advertisement

Standard Display & Error Messages
Filtration Cycle - A filtration cycle is in progress.
This flashing message will disappear on its own
once the current filtration cycle completes.
Heat - The spa is heating. This message will
disappear once the heater shuts off.
Locked - This message displays briefly whenever
access is denied the temperature setting (See
page 19).
Flow Error - The pressure switch is not registering
enough flow for safe heater operation. Check
pressure switch and pump/plumbing/water flow.
Temperature Sensor Error - The temperature
sensor is malfunctioning, or not properly
connected. Reconnect or replace temperature
sensor as needed.
Hi-Limit Sensor Error - The hi-limit sensor
is malfunctioning, or not properly connected.
Reconnect or replace temperature sensor as
needed.
Software Overheat - The temperature sensor is
reading over 116°F/46°C. Once the temperature
drops to at least 103°F/39°C press and hold the
Temp Down button for 10 seconds to reset.
Hardware Overheat - The hi-limit sensor is
reading over 118°F/48°C. Once the temperature
drops to at least 103°F/39°C press and hold the
Temp Down button for 10 seconds to reset. Until
the unit reaches 103°F/39°C Lo-Speed Pump-1
will be kept running in attempt to evenly distribute
the build-up of heat.