Interior ventilator kits

Advertisement

Available languages

Available languages

DUAL BLOWER INSTALLATION
For hood models PWC362418 and
PWC422418 using blower model 814422.
(8) 10-24 NUTS
1. Mount blower to ADAPTER PLATE (provided with blower)
with (8) 10-24 NUTS (provided).
TOP OF HOOD
KEYHOLES
2. Fasten (4) 10-24 HEX NUTS (provided) to the (4) ADAPTER
PLATE STUDS leaving a 1/4" gap.
3. Lift blower into position inside hood. Engage all adapter plate
studs into KEYHOLES in top of hood. From TOP OF HOOD,
tighten all 4 hex nuts.
4. Plug blower POWER CORD into receptacle inside the hood.
Route wires away from blower's moving parts. Bundle wires
with wire tie (provided).
ADAPTER PLATE
(4) 10-24
HEX NUTS
(4) ADAPTER
PLATE STUDS
POWER
CORD
DUAL BLOWER INSTALLATION
and all P I Series hoods using blower model
For hood models PWC482418, PWC542418
814422 and 814423.
(8) 10-24 NUTS
1. Mount blower to ADAPTER PLATE (provided with blower)
with (8) 10-24 NUTS (provided).
TOP OF HOOD
(2) THREADED
STUDS
(2) 10-24
HEX NUTS
2. Lift blower into position inside hood. Engage (2) TABS on
blower into (2) SLOTS in TOP OF HOOD. Secure blower to
(2) THREADED STUDS with (2) 10-24 HEX NUTS (provided).
3. Plug blower POWER CORD into receptacle inside the hood.
Route wires away from blower's moving parts. Bundle wires
with wire tie (provided).
MODEL • 814425
ADAPTER PLATE
(2) SLOTS
(2) TABS
POWER
CORD