Line-Lock control
Matching the vertical synchronization with the power frequency is called the Line-Lock.
G
This function is activated when the LL of Mode Setting Switch is on.
G
When two or more cameras are switched by video switcher for viewing by a monitor TV,
G
the vertical sync. phase can be locked with the power frequency, and a stable vertical
sync. is obtained without being disturbed at the time of switching.
CAMERA1
CAMERA2
16
VIDEO SWITCHER
Video Monitor
TO AC 24V UL Listed
class 2 power supply
• When connecting to DC
power supply, the Line-Lock
function is not activated.