Download Print this page

Sealey YK20FAH.V2 Instructions page 3

Air/hydraulic press 20 tonne floor type

Advertisement

6.2.
Close the release valve (41) by turning it clockwise until it is firmly closed.
6.3.
Connect the air inlet fitting into the workshop air supply hose lock fitting, turn on the air valve (40) to let the pump work until serrated
saddle (5) nears workpiece, then turn off the air valve. When air source is unavailable, pump the handle (48) until serrated saddle
nears workpiece.
6.4.
Align workpiece and ram to ensure centre-loading. Before applying any pressure to the workpiece, recheck the alignment with the ram
and ensure that the workpiece and press tools are supported in such a way that they cannot flex.
WarninG! do not apply off centre loads.
6.5.
Turn on the air valve or pump the handle to apply load onto workpiece.
6.6.
When work is done, turn off the air valve (or stop pumping handle), slowly and carefully remove load from workpiece by turning the
release valve counter-clockwise in small increments.
6.7.
once ram has fully retracted, remove workpiece from the press bed frame.
6.8.
disconnect the air inlet fitting from the air source.
note: Always keep the piston retracted after use to avoid ram corrosion.
7. Maintenance
note: maintenance and repair must only be carried out by qualified person. Contact your Sealey stockist for details.
7.1.
When the press is not in use, the hydraulic unit ram must be fully retracted to minimise corrosion. Remove the handle to inactivate the
press.
7.2.
lubricate all moving parts at regular intervals.
7.3.
Always keep the press clean, dry, and protected from harsh conditions.
7.4.
Should you need to replace the oil, ensure the hydraulic unit ram is fully retracted. An excess of oil will render the press inoperative.
7.5.
Use only appropriate Sealey hydraulic jack oil (Sealey Part number: HJo500mlS/HJo5lS). do not use brake fluid.
7.6.
Purge the system to remove any air (see 5.4).
7.7.
If press efficiency begins to drop, purge the system to eliminate any air from the hydraulic system (see 5.4).
7.8.
Check your model parts information for spares.
note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
enVironMent protection
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.