Download Print this page
Sealey YK20F Instructions

Sealey YK20F Instructions

20 ton hydraulic floor press

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND
CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
# Familiarise yourself with the applications, limitations and hazards of the press.
# Maintain the press in good condition (use an authorised service agent).
# Replace or repair damaged parts. Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
# Keep the press clean for best and safest performance.
# Locate the press in a suitable work area, on a surface that is stable, level, dry, not slippery, and capable of sustaining the load.
Keep area clean and tidy and free from unrelated materials, and ensure there is adequate lighting.
$ WARNING! Always wear approved eye or face protection when operating the press.
# Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery, and contain long hair.
# Keep hands and body clear of the work table when operating the press.
# Maintain correct balance and footing. Do not over reach. Ensure the floor is not slippery and wear non-slip shoes.
# Keep children and unauthorised persons away from the working area.
% DO NOT use the press for a task it is not designed to perform.
% DO NOT adjust or tamper with the safety valve, or make any modifications to the press.
% DO NOT exceed the rated capacity of the press. Avoid applying excessive force, use the pressure gauge to determine the applied load.
% DO NOT apply off-centre loads. Ensure that workpiece is centrally loaded and correctly secured before operating the press.
% DO NOT allow the workpiece or the arbor plates to fall from the press work bench.
% DO NOT get the press wet or use in damp or wet locations or areas where there is condensation.
% DO NOT operate the press when you are tired or under the influence of alcohol, drugs or intoxicating medication.
% DO NOT climb upon the press.
% DO NOT use if bent, broken, cracked, leaking or otherwise damaged, or if press has been subjected to a shock load.
% DO NOT operate the press if any parts are missing as this may cause failure and/or possible personal injury.
% DO NOT use the press to compress a spring or any other item that could disengage and cause a potential hazard.
% DO NOT stand directly in front of loaded press and never leave loaded press unattended.
% DO NOT allow untrained persons to operate the press.
$ WARNING: DO NOT use brake fluid, or any fluid other than a good quality jack oil, such as SEALEY HYDRAULIC JACK OIL,
as this may cause serious damage to the press and will invalidate the warranty!
# When not in use, release pressure from the pump and clean the press. Stand or store the arbors in a safe location.
2. INTRODUCTION & SPECIFICATION
2.1.
GENERAL INFORMATION
Sealey heavy-duty floor hydraulic presses are ideal for a variety of workshop applications and are particularly suited to agricultural or industrial
use. Jobs such as straightening, bending, folding, punching, removing bolts and bearings etc. are some of the tasks that may be
accomplished by this press. Fitted with a pressure gauge and supplied with work table arbors.
! DANGER! This model is purpose designed to withstand greater loads than the hydraulic unit can develop. For safety reasons, always
!
ensure the workpiece and press tools are secured on the table and will not flex or suddenly "give way" causing danger to operator or the
component.
2.2.
SPECIFICATION
Capacity
Ram stroke
Max height - ram to table
Min height - ram to table
3. ASSEMBLY
Unpack the product and check contents. Should there be any damaged or missing parts contact your supplier immediately. Take care to
ensure safety when removing main frame from packing as the unit is very heavy.
3.1.
Use the parts diagram as your guide to assembly. Lay all parts and assemblies out before beginning. The following procedure is
recommended:
3.2.
Attach one base section (21) to left post (20) and lower cross member (26) using bolts (25), washers (22), lock washers (23) and
nuts (24) to secure, then repeat with the other base section (21), attaching it to right post (20) and the lower cross member (26).
3.3.
Place the press frame in an upright position, attach one upper cross beam (10) to left and right posts (20) using bolts (9),
washers (13), lock washers (12) and nuts (11).
3.4.
Place the other upper cross beam (10) in position and insert the under plate (7) to the two upper cross beams at the same time,
then secure this cross beam to the posts using bolts (9), washers (13), lock washers (12) and nuts (11).
3.5.
Screw the upper round nut (6) onto the ram (3), insert the ram into the hole in the under plate (7), then screw the under round
nut (8) onto the ram and attach the serrated saddle (5) to the ram.
20ton
185mm
1025mm
65mm
INSTRUCTIONS FOR :
20 TON HYDRAULIC FLOOR PRESS
Y K 2 0 F
MODEL :
Table aperture
Work table width
Overall height
Gauge included
Weight
105mm
550mm
1810mm
Yes
96kg
YK20F.- 1 - 060706

Advertisement

loading

Summary of Contents for Sealey YK20F

  • Page 1 % DO NOT allow untrained persons to operate the press. $ WARNING: DO NOT use brake fluid, or any fluid other than a good quality jack oil, such as SEALEY HYDRAULIC JACK OIL, as this may cause serious damage to the press and will invalidate the warranty! # When not in use, release pressure from the pump and clean the press.