Procedure
7.3
Procedure
30322453-02-EN
CAUTION
Injury caused by working machine
If the function is activated when the implement is at a standstill, the driver can activate functions that
can otherwise only be activated during travel. This can cause injury to persons standing close to the
implement.
◦ Make sure that no one is close to the implement.
1. On the work screen, press:
> (
⇨ The desired speed will be simulated.
2. In the "Simulated speed" parameter, enter the speed to be simulated.
Calibrating the flow meter
You must calibrate the flow meter in the following cases:
▪ Prior to initial start-up.
▪ At the start of each season.
▪ If you notice that there are deviations between the applied quantity and the displayed quantity.
▪ After repairs performed on the flow meter.
NOTICE
Imprecise calibration
If the calibration is imprecise, the calculations will be very inaccurate and the application imprecise.
◦ Calibrate the flow meter very precisely.
CAUTION
Slurry or slurry residues
Risk of poisoning or corrosion
◦ Clean the tank before calibration.
◦ Only use clear water for the calibration.
◦ Wear required protective equipment.
The tank is filled with water. You need several hundred litres of water.
You have a method for measuring the quantity of applied water.
The pump is switched on.
1. Drive the slurry tanker to a position where you can apply the water without any problems.
2. On the work screen, press:
⇨ The "FLOW METER" screen appears.
> (
V4.20191001
Configuring the job computer for work
) >
>
) >
Calibrating the flow meter
>
7
47
Need help?
Do you have a question about the SLURRY-Controller 3.0 and is the answer not in the manual?