Operating Instructions
6. See
Figure
6-5. The LCD will display Testing
PRVSS
during
completion, the LCD will read Low Sun or Making
Power, depending upon available PV voltage.
Figure 6-5. PVRSS Commissioning (4 of 4)

PVRSS Commissioning Troubleshooting

If the device fails to commission properly an error message will indicate the source of the failure. See
PVRSS Commissioning Troubleshooting
Message
PVRSS fail: high input
PVRSS not configured
PVRSS count
mismatch
PVRSS fail: low input
16
the
testing
process.
010033
for common error codes and their meaning.
Table 6-1. PVRSS Commissioning Troubleshooting
Cause
The voltage detected with SnapRS
devices disabled is higher than
expected.
PVRSS is enabled on the optimizer,
but the SnapRSInstalld device
setting indicates no SnapRS devices
are installed.
The number of SnapRS devices
listed in the SnapRSInstalld device
setting does not match the detected
number of SnapRS devices.
The panel output voltage is too low
to accurately count the SnapRS
devices.
7. Complete steps 1-4 for each PV link in the system.
Upon
NOTE: To verify a PV Link is working properly, navigate
to
the
Mod.Settings
SnapRSInstalld value matches the number of SnapRS
devices connected to that PV Link.
Solution
Verify the SnapRS devices are installed correctly.
Run the PVRSS self-test.
SnapRS devices have not been installed or have failed.
If the failure persists, contact the nearest Independent
Authorized Service Dealer (IASD) or Generac Customer
Service at 1-888-436-3722 (1-888-GENERAC),
www.generac.com
Follow the instructions in the PVRSS Commissioning with
SnapRS Devices section. See
with SnapRS Devices
If the failure persists, contact the nearest Independent Autho-
rized Service Dealer (IASD) or Generac Customer Service at
1-888-436-3722 (1-888-GENERAC),
erac.com
for assistance.
Check the Mod. Settings and update the SnapRSInstalld
value to reflect the number of installed SnapRS devices.
If the error persists, contact the nearest Independent Authorized
Service Dealer (IASD) or Generac Customer Service at 1-888-
436-3722 (1-888-GENERAC),
for assistance.
If this error occurs with normal exposure to sunlight, contact the
nearest Independent Authorized Service Dealer (IASD) or Gen-
erac Customer Service at 1-888-436-3722 (1-888-GEN-
or visit
www.generac.com
ERAC),
page
and
confirm
or visit
for assistance.
PVRSS Commissioning
.
or visit
or visit
www.generac.com
for assistance.
Installation Manual for PV Link
the
Table 6-1:
www.gen-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents