OPERATING MODE
System
Thermostat
Condition
Demand
Y1
Normal operation
Normal operation
Y2
Y1
Y1
Call for humidity
removal during
removal during
1st−stage cooling
Demand
demand
satisfied
Y1
Significant increase in
Y1
humidity during
humidity during
thermostat cooling
Y1
demand.
Y1
Humidity demand
Y1
satisfied during
satisfied during
thermostat demand.
None
Y1
Y2
Call for humidity
Call for humidity
removal during 2nd
Y2
stage thermostat
demand
demand
Y2
None
*Call for 1st stage
cooling after call for
cooling after call for
humidity removal.
Y1
None
Call for 2nd stage
cooling after call for
cooling after call for
humidity removal
Y2
None
Call for cooling after
significant increase in
significant increase in
humidity
Y1 or Y2
Humidity demand
None
satisfied between
satisfied between
thermostat demands
(unit off cycle).
Y1 or Y2
Note − During mode of operation change from cooling to heating, indicating lights will not change until the first thermostat heating
demand.
*IMPORTANT - If power to unit is turned on with CCB1 calling for humidity removal, outdoor unit may be locked into high speed
indefinitely. To reset, move the humidity slide switch all the way down then back up to desired setpoint while the unit is running.
** Reduced blower speed is 77% of COOL for the V3 units; 74% of COOL for V5.
***If the two−speed control on a two−speed outdoor unit is set for LATCH 2 (15 minutes) or LATCH 3 (30 minutes), the compressor
will latch into high speed after a Y1 demand has occurred for that period of time.
TABLE 28
G32V−5, CCB1 and Two−Speed Outdoor Unit
SYSTEM DEMAND
*Relative Humidity
(EfficiencyPlus Lights)
No demand. Acceptable
No demand. Acceptable
No demand. Acceptable
Humidity level rises slightly
(1) above setpoint. Demand
initiated.
Humidity level remains
slightly (1) above setpoint.
Demand continues.
Humidity level remains
slightly (1) above setpoint.
Demand continues.
No demand. Acceptable
Humidity level rises signifi-
cantly (2 or more) above
setpoint. Demand initiated.
Humidity level
above setpoint.
Humidity level falls below
setpoint. No demand.
No demand. Acceptable
No demand. Acceptable
No demand. Acceptable
Humidity level rises slightly
(1) above setpoint. Demand
initiated.
No demand. Acceptable
Humidity level is slightly (1)
above setpoint.
Humidity level is slightly (1)
above setpoint.
Humidity level is slightly (1)
above setpoint.
Humidity level is slightly (1)
above setpoint.
Humidity level is significantly
above setpoint (2 or more).
Humidity level is significantly
above setpoint (2 or more).
Humidity level is slightly (1)
above setpoint.
Humidity level falls below
setpoint. No demand.
Page 29
SYSTEM RESPONSE
****Compressor
Blower CFM
Speed
(COOL)
55% of
Low
HIGH COOL
High
HIGH COOL
55% of
Low
HIGH COOL
55% of
Low
HIGH COOL
Off
Off
**77%/74% of
High
HIGH COOL
55% of
Low
HIGH COOL
**77%/74% of
High
HIGH COOL
**77%/74% of
High
HIGH COOL
HIGH COOL
High
Off
Off
55% of
Low
HIGH COOL
HIGH COOL
High
**77%/74% of
High
HIGH COOL
HIGH COOL
High
Off
Off
55% of
Low
HIGH COOL
Off
Off
**77%/74% of
High
HIGH COOL
Off
Off
**77%/74% of
High
HIGH COOL
Off
Off
HIGH COOL
High
Comments
Compressor demand and indoor
blower speed controlled by
blower speed controlled by
thermostat demand
Dehumidification mode does not begin
until after initial thermostat demand is
until after initial thermostat demand is
satisfied and new cooling demand is
initiated.
If humidity rises significantly above set-
point, or if slide switch is moved signifi-
point, or if slide switch is moved signifi
cantly, unit will immediately go into de-
l
i
ill i
di
l
humidification mode (in presence of
thermostat demand).
When humidity demand is satisfied,
When humidity demand is satisfied,
blower immediately shifts to the COOL
CFM in order to hasten the end of the
cycle Unit can only shift out of high
cycle. Unit can only shift out of high
speed compressor operation at begin
speed compressor operation at begin-
ning of next cycle.
Blower immediately changes speed in
response to thermostat demand.
Dehumidification mode (high speed
compressor) begins with next thermo-
compressor) begins with next thermo
stat demand after initial demand is sat-
isfied.
Reduced blower speed (dehumidifica-
tion speed) begins immediately with
tion speed) begins immediately with
thermostat demand
If humidity increases significantly over
setpoint, or if slide switch is moved,
unit immediately goes into dehumidifi-
unit immediately goes into dehumidifi
cation mode (in presence of thermostat
demand).
While unit is not operating (no thermo-
stat demand), slide switch is moved
down and back up Blower and com
down and back up. Blower and com-
pressor operate at high speed until
next thermostat demand.