Lennox G32V Series Service Literature page 24

Hide thumbs Also See for G32V Series:
Table of Contents

Advertisement

TABLE 16
Two Stage Ignition / Blower Control Terminals
LINE
XFMR
Transformer 120VAC Neutral
EAC
Electronic Air Cleaner 120VAC Neutral
CIRC
Indoor Blower 120VAC Neutral
HUM
Humidifier 120VAC Neutral
HUM
XMFR
LINE
CIRC
Indoor Blower 120VAC Hot
EAC
Electronic Air Cleaner 120VAC Hot
TABLE 17
SureLight Board 5 Pin Terminal Designation
PIN #
1
2
Combustion Air Inducer High Speed
3
Combustion Air Inducer Low Speed
4
Combustion Air Inducer Neutral
5
Line 120VAC Neutral
Humidifier 120VAC Hot
Transformer 120VAC Hot
Line 120VAC Hot
Function
Ignitor
Ignitor Neutral
SureLight Board 12Pin Terminal Designation
PIN #
1
2
3
4
5
6
7
8
9
10
11
12
SureLight Board 16 Pin Blower Control Terminals
PIN #
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Page 24
TABLE 18
Function
Gas Valve High Fire
Second Stage Prove Switch (G32V−75)
Not Used
Ground
24V Hot
Primary Limit In
Gas Valve Low Stage
Gas Valve Common
24V Neutral
Ground
Primary Limit Out
1st Stage Prove Switch
TABLE 19
Function
Ground
Low Heat Speed
Ground
DELAY" Dip Switch Selection
COOL" Dip Switch Selection
Y1" Signal
ADJUST" Dip Switch Selection
Ground
0" From Thermostat
DS" Output Signal
HEAT" Dip Switch Selection
24 VAC
HIGH HEAT Speed
Y2" Signal
G"
CFM LED