NR-211-MP WELDING PROCEDURES
HORIZONTAL, FLAT, DOWNHILL AND
Plate Size – T (in)
Pass
Electrode
Polarity
CTWD
Wire Feed Speed
(in/min)
Arc Volts
Travel Speed (in/min)
Deposit Rate (lbs/hr)
(1) Use 1 volt lower for Vertical Down and Overhead.
HORIZONTAL, FLAT, DOWNHILL
VERTICAL DOWN AND OVERHEAD
Plate Size – T (in)
Pass
Electrode
Polarity
CTWD
Wire Feed Speed
(in/min)
Arc Volts
Travel Speed (in/min)
Deposit Rate (lbs/hr)
Because design, fabrication, erection and welding variables
affect the results obtained in applying this type of information,
the serviceability of a product or structure is the responsibility
of the builder/user.
VERTICAL DOWN
1 4 GA
1
5/64" NR-211-MP MP DC( – )
.068" NR-232 DC( – )
1"
50
(1)
16
As Req'd
2.9
16 GA
1
.068" NR-211-MP MP DC( – )
.068" NR-232 DC( – )
1"
40
15
As Req'd
1.7
– 30 –
10 GA
1
1"
75
(1)
18
As Req'd
4.5
12 GA
1
1"
60
16
As Req'd
2.6