Chaffoteaux & Maury Britony FlexiFlue Installation And Servicing Instructions page 8

Table of Contents

Advertisement

3.2
Preparing and fitting
the appliance
3.3
107diam
I
9-=
A-
-I
I&
197,5 mm minimum
I
9Q
3
Preparation
:
-
Remove the bottom trim by pulling forwards.
- Slide the controls facla plate (P) upwards to disen-
gage from retaining bracket.
- Release the front case by removing the four fixing
screws and washers positioned at the top, bottom
and centre of appliance.
- Remove the front case by lifting off the top loca-
tlng lugs and pulling forward
to clear the water
section at the base of the appliance.
NOTE : A template
is not supplied with this appliance.
Particular care is therefore
necessary to ensure that
the appliance mounting bracket is frtted level and po-
sitioned accurately. When using extended flues, a fall
of 5 mm per metre length should be provided. (From
turret to terminal).
- Refer to the drawings opposite for rear and side
flue applications and/or to the dimensions given.
- Set out an drill hole flue using a 107 mm core
drill.
- Using the dimension 290 mm (11.4 in) accurately
mark position for bracket.
Drill and plug the wall.
I - Hang the appliance on the bracket, and re-check
for level. Mark bottom
fixing holes, remove ap-
pliance, drill and plug the wall to suit No. 12 screws.
- Re-hang appliance and secure with screws provi-
I
Flue Length
Minimum Wall Thickness 3 in (75 mm)
Rear Outlet
Wall thickness
up to 612.5 mm
Over 612.5 mm
Delivered with
Extension available
apphance
PI No. 62823
Flue duct length = wall thickness + 25 mm
Air inlet duct length = wall thickness + 25 mm
Pt No. 62823
= GC No 264 459
Side Outlet
EM = Wall thickness
DM = Distance from wail to case m
EM
up to
500
mm
+DM
500 mm
to 1400
Dehv
I extn
with
Pt No
appliance
62823
Flue duct length EM + DM + 130 mm
Air inlet duct length EM + DM + 130 mm
1401 mm
to 2300
2
extn.
2X
62823
2300
mm
t0
2787
3
extn.
3x
62823
8

Hide quick links: