Correct Use; Standard Delivery; Specification - Bosch WORCESTER GREENSTAR WIRING CENTRE Installation, Commissioning & Servicing Instructions

Table of Contents

Advertisement

• Pump seizure protection function:
– The connected pump is monitored and ran for a short period after
24 hours of downtime. This prevents the pump from seizing.
A maximum of three modules per system are permissible, irrespective of
the number of other BUS subscribers:
• a maximum of two modules for a total of six heating circuits without
electronic mixing valves
• a maximum of one module for two additional heating circuits without
electronic mixing valves and one cylinder charging circuit
As delivered, the code switch is set to Y. The module will therefore
operate the system as a mid-position (Y-plan). S (S-plan) or other
configurations can be selected when necessary.
2.1

CORRECT USE

The module communicates via an EMS-plus interface with other EMS-
plus-enabled BUS subscribers such as Greenstar boilers.
▶ Only use the appliance for its intended purpose.
▶ Observe all country-specific regulations and standards during
installation and operation.
2.2

STANDARD DELIVERY

5
4
Fig. 1 Scope of supply
[1]
Module
[2]
Cylinder temperature sensor (TC1)
[3]
Cylinder temperature sensor (TC1) retaining device. To enable
satisfactory installation of the cylinder temperature sensor on hot
water cylinders without sensor pockets.
[4]
Bag with installation material
[5]
Installation instructions
6 720 804 107 (2012/10)
2.3
Technical data
Dimensions (W × H × D)
Maximum conductor cross-
section
• Terminal 230 V
• Extra-low voltage connecting
Rated voltages
• BUS
• Module power supply
• Pump and mixer
Fuse
BUS interface
Power consumption –
Standby
max. power output
• per connection (PZ1 ... PZ3)
1
• per connection (IZ1 ... IZ4)
Temperature sensor
measuring range
• lower fault limit
• display range
• upper fault limit
Permissible ambient
temperature
IP rating
Id. no.
2
Table 2 Technical data
3
6 720 804 106-01.1O
Fig. 2 Dimensions

SPECIFICATION

Design and operation of this product conform to European
Directives and the supplementary national requirements. Its
conformity is demonstrated by the CE designation.
151 × 184 × 61 mm
(further dimensions  fig. 2)
• 2.5 mm
• 1.5 mm
terminal
• 15 V DC
• 230 V AC, 50 Hz
• 230 V AC, 50 Hz
230 V, 5 AT
EMS plus
< 1 W
• 400 W (high-efficiency pumps
• 230 V AC, max. 0.5 A
• < – 10 °C
• 0 ... 100 °C
• > 125 °C
0 ... 60 °C
IP 44
Type plate ( fig. 3, page 4)
72
72
246
PRODUCT DETAILS
2
2
(reverse-polarity-protected)
permissible; max. 40 A/s)
61
6 720 804 106-02.1O
3