E.
Error messages
MOD
Description
MOD S
Error message
MOD 17
SEP adivated
F.
Functions for external accessories
MOD
Description
MOD 13
Magnetic lock fundion
MOD 20
Activation of optoeledronic transmission system
MOD 21
Test of draw-in protedion
MOD 22
Test of external safety devices
MOD 24
Capacitor
MOD 2S
Yard light fundion
MOD 26
Adivation of radio transmission system
MOD 28
Relay OFF
Re marks
The relay closes the contad when a stop com mand is given or an error occurs.
All errors described in sedi on 1 O result in adivation of the relay.
The relay opens the contad when the switching strip is adivated. An error in the
switching strip or an unsuccessful test is shown via MOD S.
Rema rks
The relay is open in the CLOSED end
position.
il an OPEN com mand is received, the
relay closes and remains closed until the CLOSED end position is reached
again.
il
a time delay is required for opening the magnetic lock, this is realised through the
parameter DELAY OPEN and forewarning
.
Before every CLOSE com mand, the optoeledronic transmission system is adivated
and remains adive for the duration of the closing run.
This adivation results ina closing run delay of approx. O. S seconds.
The relay generates a test signal when the CLOSED end position is reached and
expects, as a readion
to
the test signal, that the safety circuit is adivated.
The relay generates a test signal when the OPEN end position is reached and
expeds, asa readion to the test signal, that the switching strip input circuit is
adivated.
At every drive com mand the relay closes for approx. 1 second. With the aid of this
relay, an additional starting capacitor that is required for AC applications is switched
on in addition,
to
ensure safe starting of the motor.
At every OPEN com mand, the relay is closed for 2 minutes and can the relo re be used
to control a light.
Before every CLOSE com mand the radio transmission system is adivated by an
impulse.
The duration of the adivation must be set in the transmission system.
This adivation results in a closing run delay of approx. O.S seconds.
The relay is always open.