Brake Functions - Pro-Line System CS300FU Operating Instructions Manual

Table of Contents

Advertisement

B.
Position messages
MOD
Description
MOD6
OPEN end position
MOD7
CLOSED end position
MOD8
Not OPEN end position
MOD9
Not CLOSED end position
MOD 10
Before-end position OPEN 1 PART OPEN
MOD 11
Before-end position CLOSED
MOD 12
Before-end position CLOSED to CLOSED end position
MOD 19
Before-end position OPEN to OPEN end position
C.
lmpulse signals
MOD
Description
MOD4
lmpulse when there is an OPEN com mand
MOD 27
lmpulse when OPEN end position is reached
D.
Brake functions
MOD
Description
MOD14
Bra ke
MOD15
Brake negated
Re marks
The relay closes the contact when the door is in the OPEN end position.
The relay closes the contact when the door is in the CLOSED end position.
The relay closes the contact when the door is not in the OPEN end position.
The relay closes the contact when the door is not in the CLOSED end position.
The relay closes the contact when the door is in the before-end position OPEN 1
PART OPEN.
The relay closes the contact when the door is in the before-end position CLOSED.
The relay closes the contact when the door is in the area between the end position
CLOSED and the before-end position CLOSED.
The relay closes the contact when the door is in the area between the OPEN end
position and the before-end position OPEN
1
PART OPEN.
Rema rks
The relay closes the contact for 1 second when the door receives an OPEN command.
This impulse can be used to controllights, for instance.
The relay closes the contact for 2 seconds when the door reaches the OPEN end
position.
This impulse can be used, for instance, to open a following photoelectric barrier.
Re marks
The switching contact of the bra ke rectifiers is activated via the relay to achieve a
quicker bra ke function. The contact is closed, and the bra ke released as a result,
as soon as the door moves (zero current bra ke).
The switching contact of the bra ke rectifiers is activated via the relay to achieve a
quicker bra ke function. The contact is opened, and the bra ke released as a result,
as soon as the door moves (operating current bra ke).