D
Disconnect the power supply and the connection cable before you
replace the device fuse.
➤ Disconnect the power supply to the device.
➤ Pull off the connection cable.
➤ Pry out the fuse insert (fig. 4 2, page 3) with a screwdriver.
➤ Replace the defective glass fuse with a new one that has the same type and rating
(4 A ,250 V).
➤ Press the fuse insert back into the housing.
➤ Reconnect the power supply to the device.
➤ Unscrew the contact pin housing (fig. 7 3, page 4) from the plug (fig. 7 1,
page 4).
➤ Replace the defective fuse (fig. 7 2, page 4) with a new fuse of the same type
and rating (3AG, Fast Acting, 10 A).
➤ Re-assemble the plug in reverse order.
I
There is an additional DC fuse inside the device (Automotive standard
blade fuse, 10 A). This fuse can only be replaced by an authorised repair
centre.
➤ Disconnect the power supply to the device.
➤ Pry out the transparent cover with a screwdriver (fig. 8 A, page 4).
➤ Unscrew the PCB mounting screws (fig. 8 B, page 4).
➤ Pull out the plug from the PCB (fig. 8 C, page 4).
➤ Replace the defective light PCB with a new one.
➤ Fit the new PCB using reverse of removal instructions.
➤ Press the transparent cover back into the housing.