Download Print this page
Nora Lighting NUD-88 Installation Instructions

Nora Lighting NUD-88 Installation Instructions

Ledur led undercabinet

Advertisement

Quick Links

Installation Instructions
NUD-88
LEDUR LED Undercabinet
IMPORTANT - This equipment is intended to be installed only by qualified personnel. The installation must be made in accordance with the current edition of the National Electrical Code and all
applicable state and local building codes. The final installation must be approved by the appropriate, qualified electrical/building inspector(s). Improper installation may result in a fire or electrical hazard.
Be sure the electrical power to the circuit has been disconnected before installing this electrical system.
IMPORTANT - Cet équipement est destiné à être installé uniquement par du personnel qualifié. L'installation doit être faite conformément à l'édition actuelle du Code national de l'électricité et à
tous les codes de construction locaux et nationaux applicables. L'installation finale doit être approuvée par un ou plusieurs inspecteurs qualifiés en électricité / bâtiment. Une installation incorrecte peut
entraîner un incendie ou un risque électrique. Assurez-vous que l'alimentation électrique du circuit a été déconnectée avant d'installer ce système électrique.
MOUNTING The fIxTUre
1.
Remove captive mounting screw covers.
2.
Place fixture in desired position and drive Mounting Screws Securely.
In some installations it may be desired to drill a pilot hole for the screws.
3.
Replace the Captive Mounting Screw Cover.
CaPTIve MOUNTING sCrew
CaPTIve MOUNTING sCrew
COver
NOTe: Should captive mounting not line up with application, there are key-
hole mounting holes under front cover.
JOINING MUlTIPle fIxTUres:
UsING JUMPer COrD:
1.
Remove Electrical Port Covers.
2.
Connect INPUT of Jumper cord to INPUT of electrical port.
3.
Connect OUTPUT of Jumper cord to OUTPUT of electrical port.
JUMPer COrD
6505 Gayhart Street, Commerce, CA 90040
Tel 323.767.2600 | www.noralighting.com | e-mail: nora@noralighting.com
© 2019 Nora Lighting, Inc. All rights reserved. Instructions subject to change without notice.
READ PRIOR TO ATTEMPTING INSTALLATION
ALWAYS TURN OFF MAIN POWER BEFORE INSTALLATION
INSTALLATION SHOULD BE CARRIED OUT BY YOUR LOCAL ELECTRICIAN
POwer COrD CONNeCTION
Remove the Electrical Port Cover and insert the power cord into INPUT electrical port.
eleCTrICal POrT COver
NOTe: Port covers are labeled "INPUT" and "OUTPUT".
Use "INPUT" for power and "OUTPUT" when linking to another NUD unit.
UsING eND-TO-eND CONNeCTOr:
1.
Remove Electrical Port Covers.
2.
Connect INPUT of End-to-End connector to INPUT of electrical port.
3.
Connect OUTPUT of End-to-End connector to OUTPUT of electrical port.
eND-TO-eND CONNeCTOr
(PrOvIDeD wITh eaCh fIxTUre)
INPUT
OUTPUT
050219P1
IS-NUTP12-CDR01

Advertisement

loading

Summary of Contents for Nora Lighting NUD-88

  • Page 1 Connect OUTPUT of End-to-End connector to OUTPUT of electrical port. eND-TO-eND CONNeCTOr (PrOvIDeD wITh eaCh fIxTUre) INPUT OUTPUT JUMPer COrD 6505 Gayhart Street, Commerce, CA 90040 050219P1 Tel 323.767.2600 | www.noralighting.com | e-mail: nora@noralighting.com IS-NUTP12-CDR01 © 2019 Nora Lighting, Inc. All rights reserved. Instructions subject to change without notice.
  • Page 2 NUD can also be powered using “Input” ports with a cord and plug or hard wire accessories (not included). OPeN frONT COver 6505 Gayhart Street, Commerce, CA 90040 050219P2 Tel 323.767.2600 | www.noralighting.com | e-mail: nora@noralighting.com IS-NUTP12-CDR01 © 2019 Nora Lighting, Inc. All rights reserved. Instructions subject to change without notice.