SCS
Puissance frigorifique nominale
Nominal cooling capacity
Kälteleistung, nominal
Liquide
Liquid
Raccordements
Flüssigkeit
Connections
Aspiration
Anschlüsse
Suction
Sauggas
Modèle
Model
Modell
Type
Type
Typ
Compresseur
Tension
Compressor
Supply
Verdichter
Spannung
Id
Imax
Nbre x diamètre
No. x diameter
Anz. x Durchmesser
Débit d'air
Air flow
Luftvolumenstrom
Ventilateur
Fan
Tension
Ventilator
Supply
Spannung
Puissance utile
Useful power
Leistung
Imax
Volume réservoir
Receiver volume
Sammlervolumen
DESP 97/23/CE Cat. Risque
PED 97/23/EC Risk Cat.
DGRL 97/23/EG Risikokategorie
Niveau sonore
Sound level
Schalldruckpegel
Fig.
Longueur
Lenght
Länge
Dimensions
Largeur
Dimensions
Width
Abmessungen
Breite
Hauteur
Height
Höhe
Poids
Weight
Gewicht
Modèle
Model
Modell
Nbre x diamètre
No. x diameter
Anz. x Durchmesser
Débit d'air
Air flow
Luftvolumenstrom
Ventilateur
Fan
Tension
Ventilator
Supply
Spannung
Puissance utile
Useful power
Leistung
Imax
Dégivrage électrique
Electrical defrost
Elektroabtauung
Longueur
Lenght
Länge
Dimensions
Largeur
Dimensions
Width
Abmessungen
Breite
Hauteur
Height
Höhe
Poids
Weight
Gewicht
(1) Conditions nominales au R404A :
Température de chambre +0°C.
Température extérieure +32°C.
(2) Intensité de démarrage (courant rotor bloqué) du compresseur.
(3) Intensité max. de fonctionnement.
(4) Les niveaux de pression acoustique (en dBA à 10 mètres) sont indiqués en
champ libre.
Le fonctionnement à un régime différent de ces conditions nominales peut
conduire à des résultats différents.
Les résultats obtenus sur le lieu de l'installation peuvent être différents
par rapport aux valeurs du catalogue, du fait de phénomènes de réflexion
(présence de mur, etc ...).
L'affaiblissement du niveau sonore en fonction de la distance est théorique et
les phénomènes de réflexion et de résonnance peuvent modifier le résultat, soit
au niveau global pondéré, soit sur certaines fréquences.
MEDIUM TEMPERATURE APPLICATION
ZB57 Z
(1)
kW
15,74
inch
5/8"
inch
1"1/8
GSS
ZB57 Z
ZB57KCE
TFD
(2)
A
102
(3)
A
17,6
mm
2xØ450
m³/h
9750
W
520
(3)
A
2,5
dm³
14
II
(4) dB(A)
53
3
mm
1397
mm
820
mm
803
kg
192
CAN/CAE 5247
mm
2xØ500
m³/h
12700
W
900
(3)
A
2,8
W
5100
mm
1870
mm
1115
mm
992
kg
215
(1) Nominal capacities with R404A :
Cold room temperature +0°C.
Ambient air temperature +32°C.
(2) Locked Rotor current of compressor.
(3) Max. operating current.
(4) The sound presure levels (in dB(A) at 10 meters) are mentioned in free field.
Running the equipment in conditions differing from these nominal values may
lead to different results.
The results obtained on the installation site may differ from those in this leaflet,
due to sound reflections from walls, etc.
The reduction of sound level as a function of distance is theoretical and sound
reflection and resonance may alter the results, either on total sound level or on
certain frequencies.
CARACTERISTIQUES TECHNIQUES

TECHNISCHE DATEN

ZB66 Z
ZB76 Z
16,10
17,82
5/8"
5/8"
1"3/8
1"3/8
GSS
GSS
ZB66 Z
ZB76 Z
ZB66K5E
ZB76K5E
TFD
TFD
400V/3~/50Hz
111
118
17,5
20,4
2xØ450
2xØ450
9750
9750
400V/3~/50Hz
520
520
2,5
2,5
14
II
53
3
1397
1397
820
820
803
803
215
215
CAN/CAE 5247
CAN/CAE 5247
2xØ500
2xØ500
12700
12700
400V/3~/50Hz
900
900
2,8
2,8
5100
5100
1870
1870
1115
1115
992
992
215
215
(1) Nominalbedingungen bei R404A:
Raumtemperatur +0 °C.
Außentemperatur +32 °C.
(2) Stromstärke bei Anlauf (bei blockiertem Rotor) des Verdichters.
(3) Max. Betriebsstrom.
(4) Die Schalldruckpegel (in dBa in 10 m Entfernung) sind Freifeldangaben.
Bei von diesen Nominalbedingungen abweichendem Betrieb kann es zu
anderen Ergebnissen kommen.
Die am Installationsort erzielten Ergebnisse können aufgrund von Reflexionen
(an Wänden usw.) von den Katalogwerten abweichen.
Die Abschwächung des Schalldruckpegels mit zunehmender Entfernung ist
theoretisch, und Schallreflexionen und Resonanzerscheinungen können das
Ergebnis verändern, sowohl im Ganzen wie auch bei bestimmten.

TECHNICAL DATA

NORMALKÜHLUNG
ZB95 Z
22,73
7/8"
1"3/8
GSS
ZB95 Z
ZB95K5E
TFD
140
28,2
2xØ500
14300
900
3,6
14
18
II
II
53
54
3
4
1482
1105
852
258
CAN/CAE 5267
CAN/CAE 5367
2xØ500
12200
900
2,8
5100
1870
1115
992
248
ZB114 Z
27,41
7/8"
1"5/8
GSS
ZB114 Z
ZB114K5E
TFD
174
33,3
2xØ500
14300
900
3,6
18
II
56
4
1482
1105
852
267
3xØ500
18300
1350
4,2
6900
2595
1115
992
360