Sealey Power PRODUCTS SSC12710 Instructions Manual page 9

Silent electric rotary screw compressors 270ltr belt drive 10hp

Advertisement

this display means the unit is on with low load.
this display means the unit is on with normal load.
this display means the unit is on with normal - high load.
this display means the unit is on with high load.
LED status - on
LEd
LED status 'Blinking'
LED status - on
LEd
LED status - on
LEd
LED status 'Blinking'
on / off: Push for 3 seconds to switch on or off. When the unit is
off the display shows 'off'.
tEst - to activate a condensate drainage cycle, push for 3 seconds
during normal operation.
sEt - When pushed and released during normal operation it displays
the set point value (decimal). When pushed for 10 seconds it gives
access to the condensate drain parameters programming menu (c8 &
c9). Having set new configuration values, push again to store them.
uP - When pushed whilst setting the set point or configuration values, it
increases the displayed value by one unit per second, during the first 10
seconds then by 0.1 of a second thereafter.
DoWn - When pushed whilst setting the set point or configuration
values, it decreases the displayed value by one unit per second, during
the first 10 seconds then by 0.1 of a second thereafter. When pushed
for ten seconds during normal operation, it starts an automatic test cycle
of the controller.
6.2.4 Control panel (continued)
notE: when the controller is in off position, some parts of
the system remain live. therefore, for safety purposes,
disconnect the electrical power before performing any
operation on the machine.
6.2.5. conDEnsAtE DIscHArGE PArAmEtErs ProGrAmmInG.
Push the sEt key for 10 seconds to enter the parameters
configuration menu. the display will show in sequence the set
point value, the code of the first modifiable parameter (c8 and
its value). only if strictly necessary, use the uP and/or DoWn
keys to change the displayed parameter value. Press the sEt
key to store the previously changed parameter value or to
browse the parameters without changing them. 15 seconds
after the last performed operation, the controller will return
automatically to the normal operation mode.
PARAMETER
dESCRIPTION
C8
Delay between condensate
discharges
C9
time required for condensate
discharge
notE: changes entered for timing values will be effective only after
exiting the programming, while changes to other variables will be
immediately effective. Please remember that eventual changes to the
configuration parameters of the machine could negatively affect its
efficiency. thus, changes have to be arranged in collaboration with
the manufacturer.
WARNING FOR USERS:
It's forBIDDEn to moDIfY tHE otHEr confIGurAtIon
PArAmEtErs of tHE ELEctronIc controLLEr WItHout
tHE sErVIcE cEntrE's AutHorIZAtIon AnD
coLLABorAtIon.
6.2.6 AnomALY/fAuLt WArnInG
the controller is capable of recognizing certain types of
anomalies/faults occurring in the drying circuit. In such cases,
an alarm message will blink on the display, alternated to the
current dew – point value.
compressor energised
Programming mode activated
condensate drain energised
speed of the fan = 100%
speed of the fan < 100%
RANGE
SET
vALUE
1 ÷ 999
1
(min)
1 ÷ 999
1
(sec)
Original Language Version
COdE
CAUSE
HtA
High Dew – point
value
(delayed alarm).
Ht2
Very high Dew –
point value
(immediate alarm).
LtA
Low Dew – point
value.
PF1
Interruption or short
circuit on the Ptc
probe input line.
ESA
Energy saving
mode activated.
ES2
ASt
series of alarms
very close to each
other.
Note: PF1 has priority over all other alarm messages.
6.3.
REMOTE SIGNALLING ALARM.
the dryer control board is equipped with a digital output for the
remote signalling alarm. this digital output is controlled by a
relay configured as normally open. When an alarm is detected,
this relay closes a circuit.
Proceed as follows to activate a remote alarm output:
6.3.1. the user must provide a signaller in compliance with output
relays electrical features (solenoid coil, light bulb, acoustic
signaller, ...).
6.3.2. Disconnect the dryer from electrical power supply, remove
cover and left side panel.
6.3.3. connect the signaller to the terminal blocks (see below).
The activation of the above function is at the user's
discretion. The user must purchase all necessary
installation material. Any operation which needs
access to the dryer must be carried out by qualified
personnel.
6.4.
bEFORE dRYER START UP.
Before starting the machine, make sure that all operating
parameters correspond to the nominal data outlined in this
instruction. the dryer is supplied already tested and preset for
normal operation, and does not require any calibration.
nevertheless, it is necessary to check the operating
performance during the first working hours.
OUTPUTS
ACTIONS
Alarm output on.
resettable by
refrig. compressor
switching off the
output off. fan
control board when
output on. Discharge
dew-point returns to
cycle standard.
preset range.
If it persists call our
service centre.
Alarm output on
Automatic reset
refrig. compressor
when
output off.
dew-point returns to
fan output off.
preset range.
Discharge cycle
If it persists call our
standard.
service centre.
Alarm output on.
resettable by
refrig. compressor
switching off the
output off.
control board and
fan output off.
replacing the faulty
Discharge cycle
probe.
standard.
call our service
centre.
Alarm output off.
no action
refrig. compressor
necessary.
output off.
Automatic reset.
fan output off.
Discharge cycle
standard.
Alarm output on.
call our service
refrig. compressor
centre.
output off.
fan output on.
Discharge cycle
standard.
ssc12710 & ssc12710D