7.10. ELECTRIC MOTOR MAINTENANCE.
the bearings of the electric motor are pre-lubricated and
are maintenance free. In normal conditions (ambient
temperature up to 30°c) replace the motor bearings after
every 12500 hours of use. In more adverse conditions
(ambient temperature up to 40°c) replace the motor
bearings after every 8000 hours of use. the bearings must be
replaced in any event after every 4 years.
7.11. dIAGNOSING THE ALARM COdE STATUS/ANOMALIES/
FAULTS.
Before doing any job on the compressor ensure that:
• The main ON/OFF switch is turned to the OFF position ("0")
• The EMERGENCY/STOP button is pressed down into the
security position.
• The compressor is shut-off from the compressed air system.
• The compressor and the internal pneumatic circuit are
completely de-pressurised.
If you are unable to rectify the anomaly encountered on your
compressor contact your nearest authorised service centre.
IMPORTANT WARNING - Air contaminants taken into
the compressor will affect optimum performance.
Example: Body filler dust or paint over-spray will
clog the pump intake filter and may cause internal
damage to pump/motor components.
Please note that any parts damaged by any type of
contamination will not be covered by warranty.
Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to
www.sealey.co.uk, email sales@sealey.co.uk or phone 01284 757500.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: no liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Alarm
code.
AL0
AL1
fig.21
AL2
AL3
AL4
AL5
AL6
Sole UK distributor, Sealey Group,
Kempson Way, suffolk Business Park,
Bury st. Edmunds, suffolk,
IP32 7Ar
Original Language Version
ALARM COdE CONdITIONS
Problem
Causes
Solutions
machine
Damage of
Disconnect from the main power,
stopped –
temperature
replace the temperature probe and
temperature
probe or
check the cables.
probe
electric
to restart the compressor press the
anomalies.
cable.
rEsEt button on the main board.
the
Excessive
check the oil level. check if the
machine
temperature
radiator is clean.
stops, as
of air/ oil
to restart the compressor press the
the oil
mix outlet
rEsEt key on the main board.
alarm has
from the
triggered.
screw
(105°c).
machine
Ambient
to start the machine again ensure
stopped:
temperature
the compressor installation
low
below 0°c.
environment guarantees a minimum
temperature
ambient temperature above - 5°c.
thermostat
to restart the compressor press the
tripped.
rEsEt button on the main board.
machine
Emergency
turn the emergency button
stopped: the
button
clockwise to unlock it. Press the
compressor
pressed.
reset button on the control panel.
will not start.
Wrong
switch off power to the compressor
rotation
and reverse two phases of the power
direction.
cable on the terminals for connection
of the cable line.
machine
the thermal
check if the electrical power supply
stopped-
protection
is correct, check if the three power
motor
switch of the
supply phases are more or less at
thermal
motor has
the same value. check if the cables
protection
tripped.
are firmly fitted to the terminal board.
switch
check if the electrical cables have
tripped.
melted. check if the fan in-take grill
is clean or obstructed in some way.
(paper, leaves, rags).
to restart the compressor press the
rEsEt key on the main board.
machine
the internal
check if the electrical power supply
stopped:
thermal
is correct, check if the three power
temperature
protection
supply phases are more or less at
thermostat
switch of the
the same value. check if the cables
tripped.
fan motor
are firmly fitted to the terminal board,
has tripped.
check if the electrical cables have
melted. check if the fan intake grill is
clean or obstructed in some way.
(paper, leaves, rags).
to restart the compressor press the
rEsEt key on the main board.
compressor
the suction
check if the pressure probe is
is running
valve has
working correctly and also if the
but fails to
failed to
commanding solenoid valve (nc
load.
open
solenoid valve) is working regularly.
control panel internal malfunction. (see section 5.3.9)
maintenance required. (see section 5.3.10)
01284 757500
01284 703534
ssc12710 & ssc12710D
www.sealey.co.uk