11.5. The Setting Method of JIG (Handset)
This section explains the PC setting to use command required in Check Point (Handset) (P.37).
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PQZZTG1032M
Note:
*: If you have the JIG Cable for TCD500 series
11.5.1. Connections
Connect the DC Power or Battery to BATT+ and BATT- (Handset).
Connect the JIG cable GND (black).
Connect the JIG cable UTX (yellow) and URX (red).
Note:
*: Com port names may vary depending on what your PC calls it.
(PQZZ1CD505E),
change
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
Resistor
Old value (kΩ)
R2
22
R3
22
R4
22
R7
4.7
51
KX-TG1032SK/KX-TGA101S
the
following
values
of
New value (kΩ)
3.3
3.3
4.7
10